15:20:48.519648  B4000010A  Read-Ack    Status: 00000001 00001010
15:20:49.435757  T10015000  Write-Data  Control setpoint: 80.00
15:20:49.555479  BD0015000  Write-Ack   Control setpoint: 80.00
15:20:50.464644  T00110000  Read-Data   Relative modulation level: 0.00
15:20:50.553237  BC0110000  Read-Ack    Relative modulation level: 0.00
15:20:51.510143  T80190000  Read-Data   Boiler water temperature: 0.00
15:20:51.609916  B4019352E  Read-Ack    Boiler water temperature: 53.18
15:20:52.451631  T00090000  Read-Data   Remote override room setpoint: 0.00
15:20:52.466822  R807A0000  Read-Data   DHW pump/valve operation hours: 0
15:20:52.610943  B407A76FE  Read-Ack    DHW pump/valve operation hours: 30462
15:20:52.618808  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:20:53.537911  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:20:53.538257  R007B0000  Read-Data   DHW burner operation hours: 0
15:20:53.634791  B407B00F1  Read-Ack    DHW burner operation hours: 241
15:20:53.635587  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:20:54.847126  T100E0000  Write-Data  Maximum relative modulation level: 0.00
15:20:54.853671  BD00E0000  Write-Ack   Maximum relative modulation level: 0.00
15:20:55.473462  T80000100  Read-Data   Status: 00000001 00000000
15:20:55.614160  B4000010A  Read-Ack    Status: 00000001 00001010
15:20:56.477489  T10015000  Write-Data  Control setpoint: 80.00
15:20:56.616472  BD0015000  Write-Ack   Control setpoint: 80.00
15:20:57.485656  T00110000  Read-Data   Relative modulation level: 0.00
15:20:57.628534  BC0110000  Read-Ack    Relative modulation level: 0.00
15:20:58.498279  T80190000  Read-Data   Boiler water temperature: 0.00
15:20:58.611759  BC01934C0  Read-Ack    Boiler water temperature: 52.75
15:20:59.498932  T00090000  Read-Data   Remote override room setpoint: 0.00
15:20:59.512477  R801C0000  Read-Data   Return water temperature: 0.00
15:20:59.612512  B401C2094  Read-Ack    Return water temperature: 32.58
15:20:59.622406  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:21:00.000578  Command: SC=15:21/4
15:21:00.038951  SC: 15:21/4
15:21:00.506768  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:00.522710  R801C0000  Read-Data   Return water temperature: 0.00
15:21:00.609040  B401C2094  Read-Ack    Return water temperature: 32.58
15:21:00.621020  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:00.799185  SC: 15:21/4
15:21:01.892195  T90101300  Write-Data  Room setpoint: 19.00
15:21:01.896502  B50101300  Write-Ack   Room setpoint: 19.00
15:21:02.520300  T80000100  Read-Data   Status: 00000001 00000000
15:21:02.616257  B4000010A  Read-Ack    Status: 00000001 00001010
15:21:03.530873  T10015000  Write-Data  Control setpoint: 80.00
15:21:03.664433  BD0015000  Write-Ack   Control setpoint: 80.00
15:21:04.559802  T00110000  Read-Data   Relative modulation level: 0.00
15:21:04.621972  BC0110000  Read-Ack    Relative modulation level: 0.00
15:21:05.547318  T80190000  Read-Data   Boiler water temperature: 0.00
15:21:05.635754  B40193468  Read-Ack    Boiler water temperature: 52.41
15:21:06.551591  T00090000  Read-Data   Remote override room setpoint: 0.00
15:21:06.564050  R801C0000  Read-Data   Return water temperature: 0.00
15:21:06.706340  BC01C207D  Read-Ack    Return water temperature: 32.49
15:21:06.765021  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:21:07.557405  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:07.570188  R801C0000  Read-Data   Return water temperature: 0.00
15:21:07.709065  B401C207A  Read-Ack    Return water temperature: 32.48
15:21:07.733286  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:08.935348  T101812E3  Write-Data  Room temperature: 18.89
15:21:08.943291  BD01812E3  Write-Ack   Room temperature: 18.89
15:21:09.587956  T80000100  Read-Data   Status: 00000001 00000000
15:21:09.709895  B4000010A  Read-Ack    Status: 00000001 00001010
15:21:10.569942  T10015000  Write-Data  Control setpoint: 80.00
15:21:10.710424  BD0015000  Write-Ack   Control setpoint: 80.00
15:21:11.586237  T00110000  Read-Data   Relative modulation level: 0.00
15:21:11.708949  BC0110000  Read-Ack    Relative modulation level: 0.00
15:21:12.591271  T80190000  Read-Data   Boiler water temperature: 0.00
15:21:12.712805  B4019341C  Read-Ack    Boiler water temperature: 52.11
15:21:13.683169  T00090000  Read-Data   Remote override room setpoint: 0.00
15:21:13.683801  R801C0000  Read-Data   Return water temperature: 0.00
15:21:13.750934  BC01C2066  Read-Ack    Return water temperature: 32.40
15:21:13.751628  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:21:14.602538  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:14.660874  R801C0000  Read-Data   Return water temperature: 0.00
15:21:14.711648  B401C2054  Read-Ack    Return water temperature: 32.33
15:21:14.799862  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:15.984532  T80640000  Read-Data   Remote override function: 00000000
15:21:16.000708  R801C0000  Read-Data   Return water temperature: 0.00
15:21:16.005266  B401C204F  Read-Ack    Return water temperature: 32.31
15:21:16.005980  A40640303  Read-Ack    Remote override function: 00000011
15:21:17.038335  T80000100  Read-Data   Status: 00000001 00000000
15:21:17.093831  B4000010A  Read-Ack    Status: 00000001 00001010
15:21:17.620879  T10015000  Write-Data  Control setpoint: 80.00
15:21:17.719329  BD0015000  Write-Ack   Control setpoint: 80.00
15:21:18.625364  T00110000  Read-Data   Relative modulation level: 0.00
15:21:18.738415  BC0110000  Read-Ack    Relative modulation level: 0.00
15:21:19.683151  T80190000  Read-Data   Boiler water temperature: 0.00
15:21:19.729480  B401933EE  Read-Ack    Boiler water temperature: 51.93
15:21:20.643308  T00090000  Read-Data   Remote override room setpoint: 0.00
15:21:20.653856  R801C0000  Read-Data   Return water temperature: 0.00
15:21:20.809793  BC01C2030  Read-Ack    Return water temperature: 32.19
15:21:20.821462  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:21:21.654936  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:21.660651  R801C0000  Read-Data   Return water temperature: 0.00
15:21:21.806237  BC01C2035  Read-Ack    Return water temperature: 32.21
15:21:21.824338  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:23.028179  T00050000  Read-Data   Application-specific flags: 00000000 0
15:21:23.042242  BC00500FF  Read-Ack    Application-specific flags: 00000000 255
15:21:23.665888  T80000100  Read-Data   Status: 00000001 00000000
15:21:23.814256  B4000010A  Read-Ack    Status: 00000001 00001010
15:21:24.695686  T10015000  Write-Data  Control setpoint: 80.00
15:21:24.812183  BD0015000  Write-Ack   Control setpoint: 80.00
15:21:25.676626  T00110000  Read-Data   Relative modulation level: 0.00
15:21:25.814730  BC0110000  Read-Ack    Relative modulation level: 0.00
15:21:26.678601  T80190000  Read-Data   Boiler water temperature: 0.00
15:21:26.808930  B401933CF  Read-Ack    Boiler water temperature: 51.81
15:21:27.686174  T00090000  Read-Data   Remote override room setpoint: 0.00
15:21:27.692016  R801C0000  Read-Data   Return water temperature: 0.00
15:21:27.850074  BC01C2017  Read-Ack    Return water temperature: 32.09
15:21:27.850310  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:21:28.793054  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:28.793799  R801C0000  Read-Data   Return water temperature: 0.00
15:21:28.850279  BC01C200F  Read-Ack    Return water temperature: 32.06
15:21:28.855510  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:30.073308  T001B05CC  Read-Data   Outside temperature: 5.80
15:21:30.079467  R801C0000  Read-Data   Return water temperature: 0.00
15:21:30.086269  BC01C2000  Read-Ack    Return water temperature: 32.00
15:21:30.098483  A401B061A  Read-Ack    Outside temperature: 6.10
15:21:30.701856  T80000100  Read-Data   Status: 00000001 00000000
15:21:30.808779  B4000010A  Read-Ack    Status: 00000001 00001010
15:21:31.748368  T10015000  Write-Data  Control setpoint: 80.00
15:21:31.810568  BD0015000  Write-Ack   Control setpoint: 80.00
15:21:32.713857  T00110000  Read-Data   Relative modulation level: 0.00
15:21:32.807528  BC0110000  Read-Ack    Relative modulation level: 0.00
15:21:33.783166  T80190000  Read-Data   Boiler water temperature: 0.00
15:21:33.810299  BC01933AB  Read-Ack    Boiler water temperature: 51.67
15:21:34.727591  T00090000  Read-Data   Remote override room setpoint: 0.00
15:21:34.738843  R00740000  Read-Data   Burner starts: 0
15:21:34.818360  B4074DB40  Read-Ack    Burner starts: 56128
15:21:34.832993  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:21:35.752594  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:35.752937  R80750000  Read-Data   CH pump starts: 0
15:21:35.826734  B4075AF93  Read-Ack    CH pump starts: 44947
15:21:35.835337  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:37.150295  T100E0000  Write-Data  Maximum relative modulation level: 0.00
15:21:37.154227  BD00E0000  Write-Ack   Maximum relative modulation level: 0.00
15:21:37.738950  T80000100  Read-Data   Status: 00000001 00000000
15:21:38.000896  B4000010A  Read-Ack    Status: 00000001 00001010
15:21:38.779952  T10015000  Write-Data  Control setpoint: 80.00
15:21:38.911803  BD0015000  Write-Ack   Control setpoint: 80.00
15:21:39.758094  T00110000  Read-Data   Relative modulation level: 0.00
15:21:39.908000  BC0110000  Read-Ack    Relative modulation level: 0.00
15:21:40.757842  T80190000  Read-Data   Boiler water temperature: 0.00
15:21:40.905231  BC019338F  Read-Ack    Boiler water temperature: 51.56
15:21:41.767256  T00090000  Read-Data   Remote override room setpoint: 0.00
15:21:41.772616  R80760000  Read-Data   DHW pump/valve starts: 0
15:21:41.931832  BC076779E  Read-Ack    DHW pump/valve starts: 30622
15:21:41.932527  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:21:42.771668  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:42.791718  R00770000  Read-Data   DHW burner starts: 0
15:21:42.909537  BC07752A8  Read-Ack    DHW burner starts: 21160
15:21:42.921039  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:44.153292  T90101300  Write-Data  Room setpoint: 19.00
15:21:44.158923  B50101300  Write-Ack   Room setpoint: 19.00
15:21:44.849916  T80000100  Read-Data   Status: 00000001 00000000
15:21:44.910491  B4000010A  Read-Ack    Status: 00000001 00001010
15:21:45.792445  T10015000  Write-Data  Control setpoint: 80.00
15:21:45.915158  BD0015000  Write-Ack   Control setpoint: 80.00
15:21:46.798966  T00110000  Read-Data   Relative modulation level: 0.00
15:21:46.907692  BC0110000  Read-Ack    Relative modulation level: 0.00
15:21:47.801711  T80190000  Read-Data   Boiler water temperature: 0.00
15:21:47.910894  BC019336B  Read-Ack    Boiler water temperature: 51.42
15:21:48.805097  T00090000  Read-Data   Remote override room setpoint: 0.00
15:21:48.826198  R00780000  Read-Data   Burner operation hours: 0
15:21:48.918980  B40780B1B  Read-Ack    Burner operation hours: 2843
15:21:48.923036  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:21:49.825516  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:49.830595  R80790000  Read-Data   CH pump operation hours: 0
15:21:49.908207  BC079143D  Read-Ack    CH pump operation hours: 5181
15:21:49.918951  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:51.196816  T901812E1  Write-Data  Room temperature: 18.88
15:21:51.203018  B501812E1  Write-Ack   Room temperature: 18.88
15:21:51.827012  T80000100  Read-Data   Status: 00000001 00000000
15:21:51.916635  B4000010A  Read-Ack    Status: 00000001 00001010
15:21:52.832995  T10015000  Write-Data  Control setpoint: 80.00
15:21:52.930820  BD0015000  Write-Ack   Control setpoint: 80.00
15:21:53.885443  T00110000  Read-Data   Relative modulation level: 0.00
15:21:53.930532  BC0110000  Read-Ack    Relative modulation level: 0.00
15:21:54.931303  T80190000  Read-Data   Boiler water temperature: 0.00
15:21:55.006926  BC0193345  Read-Ack    Boiler water temperature: 51.27
15:21:55.857511  T00090000  Read-Data   Remote override room setpoint: 0.00
15:21:55.862019  R807A0000  Read-Data   DHW pump/valve operation hours: 0
15:21:56.008790  B407A76FE  Read-Ack    DHW pump/valve operation hours: 30462
15:21:56.019526  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:21:56.906581  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:56.906915  R007B0000  Read-Data   DHW burner operation hours: 0
15:21:57.038595  B407B00F1  Read-Ack    DHW burner operation hours: 241
15:21:57.039189  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:21:58.240414  T00740000  Read-Data   Burner starts: 0
15:21:58.245771  B4074DB40  Read-Ack    Burner starts: 56128
15:21:58.865172  T80000100  Read-Data   Status: 00000001 00000000
15:21:59.010017  B4000010A  Read-Ack    Status: 00000001 00001010
15:21:59.881689  T10015000  Write-Data  Control setpoint: 80.00
15:22:00.001189  Command: SC=15:22/4
15:22:00.053620  BD0015000  Write-Ack   Control setpoint: 80.00
15:22:00.053981  SC: 15:22/4
15:22:00.865171  SC: 15:22/4
15:22:00.885589  T00110000  Read-Data   Relative modulation level: 0.00
15:22:01.008334  BC0110000  Read-Ack    Relative modulation level: 0.00
15:22:01.890230  T80190000  Read-Data   Boiler water temperature: 0.00
15:22:02.010478  B40193328  Read-Ack    Boiler water temperature: 51.16
15:22:02.936319  T00090000  Read-Data   Remote override room setpoint: 0.00
15:22:02.936981  R801C0000  Read-Data   Return water temperature: 0.00
15:22:03.006464  B401C1FB3  Read-Ack    Return water temperature: 31.70
15:22:03.018446  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:22:03.912206  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:03.913039  R801C0000  Read-Data   Return water temperature: 0.00
15:22:04.013665  B401C1FB5  Read-Ack    Return water temperature: 31.71
15:22:04.021837  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:05.280102  T00050000  Read-Data   Application-specific flags: 00000000 0
15:22:05.289695  BC00500FF  Read-Ack    Application-specific flags: 00000000 255
15:22:05.915503  T80000100  Read-Data   Status: 00000001 00000000
15:22:06.009590  B4000010A  Read-Ack    Status: 00000001 00001010
15:22:06.973313  T10015000  Write-Data  Control setpoint: 80.00
15:22:07.015316  BD0015000  Write-Ack   Control setpoint: 80.00
15:22:07.926474  T00110000  Read-Data   Relative modulation level: 0.00
15:22:08.034200  BC0110000  Read-Ack    Relative modulation level: 0.00
15:22:08.936871  T80190000  Read-Data   Boiler water temperature: 0.00
15:22:09.055414  B40193311  Read-Ack    Boiler water temperature: 51.07
15:22:09.977920  T00090000  Read-Data   Remote override room setpoint: 0.00
15:22:09.978587  R801C0000  Read-Data   Return water temperature: 0.00
15:22:10.031325  BC01C1FEB  Read-Ack    Return water temperature: 31.92
15:22:10.041215  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:22:10.954051  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:10.954650  R801C0000  Read-Data   Return water temperature: 0.00
15:22:11.109441  BC01C2000  Read-Ack    Return water temperature: 32.00
15:22:11.119880  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:12.381882  T001B05CC  Read-Data   Outside temperature: 5.80
15:22:12.387416  R801C0000  Read-Data   Return water temperature: 0.00
15:22:12.388026  BC01C2000  Read-Ack    Return water temperature: 32.00
15:22:12.388533  A401B061A  Read-Ack    Outside temperature: 6.10
15:22:12.955300  T80000100  Read-Data   Status: 00000001 00000000
15:22:13.108967  B4000010A  Read-Ack    Status: 00000001 00001010
15:22:14.069261  T10015000  Write-Data  Control setpoint: 80.00
15:22:14.109273  BD0015000  Write-Ack   Control setpoint: 80.00
15:22:14.967619  T00110000  Read-Data   Relative modulation level: 0.00
15:22:15.109024  BC0110000  Read-Ack    Relative modulation level: 0.00
15:22:15.971078  T80190000  Read-Data   Boiler water temperature: 0.00
15:22:16.110274  B4019330F  Read-Ack    Boiler water temperature: 51.06
15:22:16.978569  T00090000  Read-Data   Remote override room setpoint: 0.00
15:22:16.988423  R801C0000  Read-Data   Return water temperature: 0.00
15:22:17.109038  BC01C202B  Read-Ack    Return water temperature: 32.17
15:22:17.122028  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:22:17.985888  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:17.996525  R801C0000  Read-Data   Return water temperature: 0.00
15:22:18.171275  BC01C2035  Read-Ack    Return water temperature: 32.21
15:22:18.171971  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:19.380681  T100E0000  Write-Data  Maximum relative modulation level: 0.00
15:22:19.384963  BD00E0000  Write-Ack   Maximum relative modulation level: 0.00
15:22:20.068669  T80000100  Read-Data   Status: 00000001 00000000
15:22:20.107675  B4000010A  Read-Ack    Status: 00000001 00001010
15:22:21.006278  T10015000  Write-Data  Control setpoint: 80.00
15:22:21.108161  BD0015000  Write-Ack   Control setpoint: 80.00
15:22:22.009688  T00110000  Read-Data   Relative modulation level: 0.00
15:22:22.106889  BC0110000  Read-Ack    Relative modulation level: 0.00
15:22:23.022413  T80190000  Read-Data   Boiler water temperature: 0.00
15:22:23.106973  BC019331C  Read-Ack    Boiler water temperature: 51.11
15:22:24.023553  T00090000  Read-Data   Remote override room setpoint: 0.00
15:22:24.035197  R801C0000  Read-Data   Return water temperature: 0.00
15:22:24.145558  B401C206E  Read-Ack    Return water temperature: 32.43
15:22:24.145895  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:22:25.049935  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:25.055003  R801C0000  Read-Data   Return water temperature: 0.00
15:22:25.117394  BC01C2082  Read-Ack    Return water temperature: 32.51
15:22:25.134384  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:26.410010  T90101300  Write-Data  Room setpoint: 19.00
15:22:26.415527  B50101300  Write-Ack   Room setpoint: 19.00
15:22:27.061931  T80000100  Read-Data   Status: 00000001 00000000
15:22:27.129092  B4000010A  Read-Ack    Status: 00000001 00001010
15:22:28.045844  T10015000  Write-Data  Control setpoint: 80.00
15:22:28.209055  BD0015000  Write-Ack   Control setpoint: 80.00
15:22:29.049961  T00110000  Read-Data   Relative modulation level: 0.00
15:22:29.207823  BC0110000  Read-Ack    Relative modulation level: 0.00
15:22:30.100606  T80190000  Read-Data   Boiler water temperature: 0.00
15:22:30.210321  B40193342  Read-Ack    Boiler water temperature: 51.26
15:22:31.065126  T00090000  Read-Data   Remote override room setpoint: 0.00
15:22:31.069346  R801C0000  Read-Data   Return water temperature: 0.00
15:22:31.208054  BC01C20C0  Read-Ack    Return water temperature: 32.75
15:22:31.228788  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:22:32.070691  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:32.080288  R801C0000  Read-Data   Return water temperature: 0.00
15:22:32.208483  BC01C20E8  Read-Ack    Return water temperature: 32.91
15:22:32.220576  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:33.451034  T101812DC  Write-Data  Room temperature: 18.86
15:22:33.460343  BD01812DC  Write-Ack   Room temperature: 18.86
15:22:34.080176  T80000100  Read-Data   Status: 00000001 00000000
15:22:34.212068  B4000010A  Read-Ack    Status: 00000001 00001010
15:22:35.088779  T10015000  Write-Data  Control setpoint: 80.00
15:22:35.209015  BD0015000  Write-Ack   Control setpoint: 80.00
15:22:36.090084  T00110000  Read-Data   Relative modulation level: 0.00
15:22:36.211656  BC0110000  Read-Ack    Relative modulation level: 0.00
15:22:37.105661  T80190000  Read-Data   Boiler water temperature: 0.00
15:22:37.212995  BC0193380  Read-Ack    Boiler water temperature: 51.50
15:22:38.102489  T00090000  Read-Data   Remote override room setpoint: 0.00
15:22:38.115059  R801C0000  Read-Data   Return water temperature: 0.00
15:22:38.212023  BC01C2138  Read-Ack    Return water temperature: 33.22
15:22:38.222357  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:22:39.112282  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:39.121655  R00740000  Read-Data   Burner starts: 0
15:22:39.276529  B4074DB40  Read-Ack    Burner starts: 56128
15:22:39.277285  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:40.499585  T00770000  Read-Data   DHW burner starts: 0
15:22:40.503127  BC07752A8  Read-Ack    DHW burner starts: 21160
15:22:41.127099  T80000100  Read-Data   Status: 00000001 00000000
15:22:41.216936  B4000010A  Read-Ack    Status: 00000001 00001010
15:22:42.134383  T10015000  Write-Data  Control setpoint: 80.00
15:22:42.220766  BD0015000  Write-Ack   Control setpoint: 80.00
15:22:43.156612  T00110000  Read-Data   Relative modulation level: 0.00
15:22:43.248354  BC0110000  Read-Ack    Relative modulation level: 0.00
15:22:44.139780  T80190000  Read-Data   Boiler water temperature: 0.00
15:22:44.234814  B401933C5  Read-Ack    Boiler water temperature: 51.77
15:22:45.165175  T00090000  Read-Data   Remote override room setpoint: 0.00
15:22:45.165859  R80750000  Read-Data   CH pump starts: 0
15:22:45.311584  B4075AF93  Read-Ack    CH pump starts: 44947
15:22:45.322252  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:22:46.155992  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:46.163099  R80760000  Read-Data   DHW pump/valve starts: 0
15:22:46.312254  BC076779E  Read-Ack    DHW pump/valve starts: 30622
15:22:46.316833  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:47.533632  T00050000  Read-Data   Application-specific flags: 00000000 0
15:22:47.538407  BC00500FF  Read-Ack    Application-specific flags: 00000000 255
15:22:48.168696  T80000100  Read-Data   Status: 00000001 00000000
15:22:48.310069  B4000010A  Read-Ack    Status: 00000001 00001010
15:22:49.224546  T10015000  Write-Data  Control setpoint: 80.00
15:22:49.337937  BD0015000  Write-Ack   Control setpoint: 80.00
15:22:50.171788  T00110000  Read-Data   Relative modulation level: 0.00
15:22:50.309329  BC0110000  Read-Ack    Relative modulation level: 0.00
15:22:51.186301  T80190000  Read-Data   Boiler water temperature: 0.00
15:22:51.307621  BC0193417  Read-Ack    Boiler water temperature: 52.09
15:22:52.188893  T10012FB3  Write-Data  Control setpoint: 47.70
15:22:52.318922  BD0012FB3  Write-Ack   Control setpoint: 47.70
15:22:53.192116  T900E6400  Write-Data  Maximum relative modulation level: 100.00
15:22:53.310094  B500E6400  Write-Ack   Maximum relative modulation level: 100.00
15:22:54.198195  T00090000  Read-Data   Remote override room setpoint: 0.00
15:22:54.210106  R00770000  Read-Data   DHW burner starts: 0
15:22:54.307308  BC07752A8  Read-Ack    DHW burner starts: 21160
15:22:54.322531  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:22:55.268156  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:55.268780  R00780000  Read-Data   Burner operation hours: 0
15:22:55.309440  B40780B1B  Read-Ack    Burner operation hours: 2843
15:22:55.318807  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:22:56.588210  T001B05CC  Read-Data   Outside temperature: 5.80
15:22:56.600025  R80790000  Read-Data   CH pump operation hours: 0
15:22:56.600598  BC079143D  Read-Ack    CH pump operation hours: 5181
15:22:56.616410  A401B061A  Read-Ack    Outside temperature: 6.10
15:22:57.224102  T80000100  Read-Data   Status: 00000001 00000000
15:22:57.317515  B4000010A  Read-Ack    Status: 00000001 00001010
15:22:58.230237  T10012FB3  Write-Data  Control setpoint: 47.70
15:22:58.324029  BD0012FB3  Write-Ack   Control setpoint: 47.70
15:22:59.304064  T00110000  Read-Data   Relative modulation level: 0.00
15:22:59.330020  BC0110000  Read-Ack    Relative modulation level: 0.00
15:23:00.000843  Command: SC=15:23/4
15:23:00.034292  SC: 15:23/4
15:23:00.241571  T80190000  Read-Data   Boiler water temperature: 0.00
15:23:00.412399  B40193497  Read-Ack    Boiler water temperature: 52.59
15:23:00.857149  SC: 15:23/4
15:23:01.246879  T00090000  Read-Data   Remote override room setpoint: 0.00
15:23:01.271417  R807A0000  Read-Data   DHW pump/valve operation hours: 0
15:23:01.408714  B407A76FE  Read-Ack    DHW pump/valve operation hours: 30462
15:23:01.426180  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:23:02.253929  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:02.265436  R007B0000  Read-Data   DHW burner operation hours: 0
15:23:02.407429  B407B00F1  Read-Ack    DHW burner operation hours: 241
15:23:02.472934  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:03.632944  T900E6400  Write-Data  Maximum relative modulation level: 100.00
15:23:03.657870  B500E6400  Write-Ack   Maximum relative modulation level: 100.00
15:23:04.270541  T80000100  Read-Data   Status: 00000001 00000000
15:23:04.465484  B4000010A  Read-Ack    Status: 00000001 00001010
15:23:05.273675  T10012FB3  Write-Data  Control setpoint: 47.70
15:23:05.451464  BD0012FB3  Write-Ack   Control setpoint: 47.70
15:23:06.278169  T00110000  Read-Data   Relative modulation level: 0.00
15:23:06.408319  BC0110000  Read-Ack    Relative modulation level: 0.00
15:23:07.295338  T80190000  Read-Data   Boiler water temperature: 0.00
15:23:07.444328  BC01934F5  Read-Ack    Boiler water temperature: 52.96
15:23:08.290424  T00090000  Read-Data   Remote override room setpoint: 0.00
15:23:08.303449  R801C0000  Read-Data   Return water temperature: 0.00
15:23:08.406400  BC01C2335  Read-Ack    Return water temperature: 35.21
15:23:08.470342  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:23:09.298508  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:09.303776  R801C0000  Read-Data   Return water temperature: 0.00
15:23:09.403297  B401C2340  Read-Ack    Return water temperature: 35.25
15:23:09.422646  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:10.735016  T90101300  Write-Data  Room setpoint: 19.00
15:23:10.738823  B50101300  Write-Ack   Room setpoint: 19.00
15:23:11.309055  T80000100  Read-Data   Status: 00000001 00000000
15:23:11.435181  B4000010A  Read-Ack    Status: 00000001 00001010
15:23:12.311052  T10012FE6  Write-Data  Control setpoint: 47.90
15:23:12.410195  BD0012FE6  Write-Ack   Control setpoint: 47.90
15:23:13.321247  T00110000  Read-Data   Relative modulation level: 0.00
15:23:13.407803  BC0110000  Read-Ack    Relative modulation level: 0.00
15:23:14.337136  T80190000  Read-Data   Boiler water temperature: 0.00
15:23:14.500581  BC0193557  Read-Ack    Boiler water temperature: 53.34
15:23:15.333126  T00090000  Read-Data   Remote override room setpoint: 0.00
15:23:15.339359  R801C0000  Read-Data   Return water temperature: 0.00
15:23:15.426875  B401C239E  Read-Ack    Return water temperature: 35.62
15:23:15.436471  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:23:16.362842  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:16.363173  R801C0000  Read-Data   Return water temperature: 0.00
15:23:16.430879  B401C23AE  Read-Ack    Return water temperature: 35.68
15:23:16.507659  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:17.719435  T901812D7  Write-Data  Room temperature: 18.84
15:23:17.724219  B501812D7  Write-Ack   Room temperature: 18.84
15:23:18.351103  T80000100  Read-Data   Status: 00000001 00000000
15:23:18.421608  Command (via web API from 10.250.250.180:44960): OT=6.2000000000000002
15:23:18.468892  OT: 6.20
15:23:18.507001  B4000010A  Read-Ack    Status: 00000001 00001010
15:23:19.402689  T10013000  Write-Data  Control setpoint: 48.00
15:23:19.502184  BD0013000  Write-Ack   Control setpoint: 48.00
15:23:20.366152  T00110000  Read-Data   Relative modulation level: 0.00
15:23:20.516508  BC0110000  Read-Ack    Relative modulation level: 0.00
15:23:21.369223  T80190000  Read-Data   Boiler water temperature: 0.00
15:23:21.506780  B401935B8  Read-Ack    Boiler water temperature: 53.72
15:23:22.377963  T00090000  Read-Data   Remote override room setpoint: 0.00
15:23:22.387659  R801C0000  Read-Data   Return water temperature: 0.00
15:23:22.520910  BC01C241C  Read-Ack    Return water temperature: 36.11
15:23:22.521719  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:23:23.382172  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:23.388943  R801C0000  Read-Data   Return water temperature: 0.00
15:23:23.506919  B401C242E  Read-Ack    Return water temperature: 36.18
15:23:23.518679  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:24.762365  T00780000  Read-Data   Burner operation hours: 0
15:23:24.770383  B40780B1B  Read-Ack    Burner operation hours: 2843
15:23:25.405966  T80000100  Read-Data   Status: 00000001 00000000
15:23:25.513583  B4000010A  Read-Ack    Status: 00000001 00001010
15:23:26.400153  T90013019  Write-Data  Control setpoint: 48.10
15:23:26.506647  B50013019  Write-Ack   Control setpoint: 48.10
15:23:27.401545  T00110000  Read-Data   Relative modulation level: 0.00
15:23:27.507448  BC0110000  Read-Ack    Relative modulation level: 0.00
15:23:28.411674  T80190000  Read-Data   Boiler water temperature: 0.00
15:23:28.507733  B4019360A  Read-Ack    Boiler water temperature: 54.04
15:23:29.416887  T00090000  Read-Data   Remote override room setpoint: 0.00
15:23:29.430646  R801C0000  Read-Data   Return water temperature: 0.00
15:23:29.506887  B401C2482  Read-Ack    Return water temperature: 36.51
15:23:29.521818  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:23:30.488417  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:30.488711  R801C0000  Read-Data   Return water temperature: 0.00
15:23:30.542100  BC01C248C  Read-Ack    Return water temperature: 36.55
15:23:30.542816  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:31.864713  T00050000  Read-Data   Application-specific flags: 00000000 0
15:23:31.869236  BC00500FF  Read-Ack    Application-specific flags: 00000000 255
15:23:32.468034  T80000100  Read-Data   Status: 00000001 00000000
15:23:32.530721  B4000010A  Read-Ack    Status: 00000001 00001010
15:23:33.446972  T10013033  Write-Data  Control setpoint: 48.20
15:23:33.607853  BD0013033  Write-Ack   Control setpoint: 48.20
15:23:34.470826  T00110000  Read-Data   Relative modulation level: 0.00
15:23:34.609207  BC0110000  Read-Ack    Relative modulation level: 0.00
15:23:35.519060  T80190000  Read-Data   Boiler water temperature: 0.00
15:23:35.625603  B40193666  Read-Ack    Boiler water temperature: 54.40
15:23:36.467589  T00090000  Read-Data   Remote override room setpoint: 0.00
15:23:36.471851  R801C0000  Read-Data   Return water temperature: 0.00
15:23:36.606427  BC01C2500  Read-Ack    Return water temperature: 37.00
15:23:36.616199  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:23:37.471048  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:37.478229  R801C0000  Read-Data   Return water temperature: 0.00
15:23:37.606025  BC01C2500  Read-Ack    Return water temperature: 37.00
15:23:37.665681  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:38.846871  T001B05CC  Read-Data   Outside temperature: 5.80
15:23:38.853605  R801C0000  Read-Data   Return water temperature: 0.00
15:23:38.858312  BC01C2514  Read-Ack    Return water temperature: 37.08
15:23:38.864206  A401B0634  Read-Ack    Outside temperature: 6.20
15:23:39.504487  T80000100  Read-Data   Status: 00000001 00000000
15:23:39.606987  B4000010A  Read-Ack    Status: 00000001 00001010
15:23:40.500079  T10013033  Write-Data  Control setpoint: 48.20
15:23:40.608159  BD0013033  Write-Ack   Control setpoint: 48.20
15:23:41.504895  T00110000  Read-Data   Relative modulation level: 0.00
15:23:41.606041  BC0110000  Read-Ack    Relative modulation level: 0.00
15:23:42.510784  T80190000  Read-Data   Boiler water temperature: 0.00
15:23:42.607350  BC01936B5  Read-Ack    Boiler water temperature: 54.71
15:23:43.504186  T00090000  Read-Data   Remote override room setpoint: 0.00
15:23:43.515160  R801C0000  Read-Data   Return water temperature: 0.00
15:23:43.642076  B401C2551  Read-Ack    Return water temperature: 37.32
15:23:43.642592  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:23:44.512300  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:44.523214  R00740000  Read-Data   Burner starts: 0
15:23:44.610399  B4074DB40  Read-Ack    Burner starts: 56128
15:23:44.616266  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:45.895674  T900E6400  Write-Data  Maximum relative modulation level: 100.00
15:23:45.900070  B500E6400  Write-Ack   Maximum relative modulation level: 100.00
15:23:46.641995  T80000100  Read-Data   Status: 00000001 00000000
15:23:46.642675  B4000010A  Read-Ack    Status: 00000001 00001010
15:23:47.531619  T10013033  Write-Data  Control setpoint: 48.20
15:23:47.619797  BD0013033  Write-Ack   Control setpoint: 48.20
15:23:48.539248  T00110000  Read-Data   Relative modulation level: 0.00
15:23:48.629728  BC0110000  Read-Ack    Relative modulation level: 0.00
15:23:49.625158  T80190000  Read-Data   Boiler water temperature: 0.00
15:23:49.771654  BC0193717  Read-Ack    Boiler water temperature: 55.09
15:23:50.546700  T00090000  Read-Data   Remote override room setpoint: 0.00
15:23:50.560580  R80750000  Read-Data   CH pump starts: 0
15:23:50.722709  B4075AF93  Read-Ack    CH pump starts: 44947
15:23:50.728355  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:23:51.563766  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:51.586392  R80760000  Read-Data   DHW pump/valve starts: 0
15:23:51.706669  BC076779E  Read-Ack    DHW pump/valve starts: 30622
15:23:51.719351  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:52.936459  T90101300  Write-Data  Room setpoint: 19.00
15:23:52.941463  B50101300  Write-Ack   Room setpoint: 19.00
15:23:53.568194  T80000100  Read-Data   Status: 00000001 00000000
15:23:53.759283  B4000010A  Read-Ack    Status: 00000001 00001010
15:23:54.593885  T10013033  Write-Data  Control setpoint: 48.20
15:23:54.708171  BD0013033  Write-Ack   Control setpoint: 48.20
15:23:55.713284  T00110000  Read-Data   Relative modulation level: 0.00
15:23:55.717302  BC0110000  Read-Ack    Relative modulation level: 0.00
15:23:56.585466  T80190000  Read-Data   Boiler water temperature: 0.00
15:23:56.705859  B40193775  Read-Ack    Boiler water temperature: 55.46
15:23:57.590104  T00090000  Read-Data   Remote override room setpoint: 0.00
15:23:57.604286  R00770000  Read-Data   DHW burner starts: 0
15:23:57.706028  BC07752A8  Read-Ack    DHW burner starts: 21160
15:23:57.717711  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:23:58.604238  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:58.604531  R00780000  Read-Data   Burner operation hours: 0
15:23:58.723809  B40780B1B  Read-Ack    Burner operation hours: 2843
15:23:58.724575  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:23:59.981455  T901812D7  Write-Data  Room temperature: 18.84
15:24:00.000659  Command: SC=15:24/4
15:24:00.001491  B501812D7  Write-Ack   Room temperature: 18.84
15:24:00.068259  SC: 15:24/4
15:24:00.633443  T80000100  Read-Data   Status: 00000001 00000000
15:24:00.712895  B4000010A  Read-Ack    Status: 00000001 00001010
15:24:00.804197  SC: 15:24/4
15:24:01.615779  T9001304C  Write-Data  Control setpoint: 48.30
15:24:01.712754  B5001304C  Write-Ack   Control setpoint: 48.30
15:24:02.622688  T00110000  Read-Data   Relative modulation level: 0.00
15:24:02.710014  BC0110000  Read-Ack    Relative modulation level: 0.00
15:24:03.627053  T80190000  Read-Data   Boiler water temperature: 0.00
15:24:03.721658  BC01937CF  Read-Ack    Boiler water temperature: 55.81
15:24:04.634768  T00090000  Read-Data   Remote override room setpoint: 0.00
15:24:04.643270  R80790000  Read-Data   CH pump operation hours: 0
15:24:04.726270  BC079143D  Read-Ack    CH pump operation hours: 5181
15:24:04.742977  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:24:05.646766  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:05.653985  R807A0000  Read-Data   DHW pump/valve operation hours: 0
15:24:05.808511  B407A76FE  Read-Ack    DHW pump/valve operation hours: 30462
15:24:05.813596  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:07.022406  T007B0000  Read-Data   DHW burner operation hours: 0
15:24:07.027952  B407B00F1  Read-Ack    DHW burner operation hours: 241
15:24:07.655450  T80000100  Read-Data   Status: 00000001 00000000
15:24:07.806435  B4000010A  Read-Ack    Status: 00000001 00001010
15:24:08.674855  T9001304C  Write-Data  Control setpoint: 48.30
15:24:08.837191  B5001304C  Write-Ack   Control setpoint: 48.30
15:24:09.664321  T00110000  Read-Data   Relative modulation level: 0.00
15:24:09.857349  BC0110000  Read-Ack    Relative modulation level: 0.00
15:24:10.668733  T80190000  Read-Data   Boiler water temperature: 0.00
15:24:10.805502  BC0193821  Read-Ack    Boiler water temperature: 56.13
15:24:11.702324  T00090000  Read-Data   Remote override room setpoint: 0.00
15:24:11.703024  R007B0000  Read-Data   DHW burner operation hours: 0
15:24:11.823796  B407B00F1  Read-Ack    DHW burner operation hours: 241
15:24:11.824099  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:24:12.690928  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:12.691561  R801C0000  Read-Data   Return water temperature: 0.00
15:24:12.810821  B401C26A1  Read-Ack    Return water temperature: 38.63
15:24:12.831534  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:14.070601  T00050000  Read-Data   Application-specific flags: 00000000 0
15:24:14.078546  BC00500FF  Read-Ack    Application-specific flags: 00000000 255
15:24:14.696023  T80000100  Read-Data   Status: 00000001 00000000
15:24:14.812765  B4000010A  Read-Ack    Status: 00000001 00001010
15:24:15.752992  T9001304C  Write-Data  Control setpoint: 48.30
15:24:15.895565  B5001304C  Write-Ack   Control setpoint: 48.30
15:24:16.708921  T00110000  Read-Data   Relative modulation level: 0.00
15:24:16.814339  BC0110000  Read-Ack    Relative modulation level: 0.00
15:24:17.718257  T80190000  Read-Data   Boiler water temperature: 0.00
15:24:17.806321  BC0193863  Read-Ack    Boiler water temperature: 56.39
15:24:18.724003  T00090000  Read-Data   Remote override room setpoint: 0.00
15:24:18.733560  R801C0000  Read-Data   Return water temperature: 0.00
15:24:18.812875  BC01C26F0  Read-Ack    Return water temperature: 38.94
15:24:18.828443  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:24:19.729617  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:19.740314  R801C0000  Read-Data   Return water temperature: 0.00
15:24:19.824033  BC01C2702  Read-Ack    Return water temperature: 39.01
15:24:19.838561  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:21.109613  T801B05E6  Read-Data   Outside temperature: 5.90
15:24:21.128851  R801C0000  Read-Data   Return water temperature: 0.00
15:24:21.129449  BC01C2702  Read-Ack    Return water temperature: 39.01
15:24:21.130084  A401B0634  Read-Ack    Outside temperature: 6.20
15:24:21.799528  T80000100  Read-Data   Status: 00000001 00000000
15:24:21.920946  B4000010A  Read-Ack    Status: 00000001 00001010
15:24:22.747297  T10013066  Write-Data  Control setpoint: 48.40
15:24:22.906703  BD0013066  Write-Ack   Control setpoint: 48.40
15:24:23.755291  T00110000  Read-Data   Relative modulation level: 0.00
15:24:23.906208  BC0110000  Read-Ack    Relative modulation level: 0.00
15:24:24.768012  T80190000  Read-Data   Boiler water temperature: 0.00
15:24:24.957940  BC01938A6  Read-Ack    Boiler water temperature: 56.65
15:24:25.765628  T00090000  Read-Data   Remote override room setpoint: 0.00
15:24:25.777365  R801C0000  Read-Data   Return water temperature: 0.00
15:24:25.949178  B401C2735  Read-Ack    Return water temperature: 39.21
15:24:25.949603  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:24:26.798235  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:26.798969  R801C0000  Read-Data   Return water temperature: 0.00
15:24:26.913346  BC01C2738  Read-Ack    Return water temperature: 39.22
15:24:26.913770  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:28.152652  T900E6400  Write-Data  Maximum relative modulation level: 100.00
15:24:28.170334  B500E6400  Write-Ack   Maximum relative modulation level: 100.00
15:24:28.782914  T80000100  Read-Data   Status: 00000001 00000000
15:24:28.905010  B4000010A  Read-Ack    Status: 00000001 00001010
15:24:29.797736  T90013080  Write-Data  Control setpoint: 48.50
15:24:29.907685  B50013080  Write-Ack   Control setpoint: 48.50
15:24:30.820394  T00110000  Read-Data   Relative modulation level: 0.00
15:24:30.937139  BC0110000  Read-Ack    Relative modulation level: 0.00
15:24:31.816568  T80190000  Read-Data   Boiler water temperature: 0.00
15:24:31.904707  B401938E3  Read-Ack    Boiler water temperature: 56.89
15:24:32.809050  T00090000  Read-Data   Remote override room setpoint: 0.00
15:24:32.820706  R801C0000  Read-Data   Return water temperature: 0.00
15:24:32.915446  BC01C2768  Read-Ack    Return water temperature: 39.41
15:24:32.915794  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:24:33.820916  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:33.826313  R801C0000  Read-Data   Return water temperature: 0.00
15:24:33.924335  BC01C276B  Read-Ack    Return water temperature: 39.42
15:24:33.925124  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:35.210521  T90101300  Write-Data  Room setpoint: 19.00
15:24:35.214267  B50101300  Write-Ack   Room setpoint: 19.00
15:24:35.828520  T80000100  Read-Data   Status: 00000001 00000000
15:24:35.919006  B4000010A  Read-Ack    Status: 00000001 00001010
15:24:36.833913  T90013080  Write-Data  Control setpoint: 48.50
15:24:36.930800  B50013080  Write-Ack   Control setpoint: 48.50
15:24:37.862882  T00110000  Read-Data   Relative modulation level: 0.00
15:24:38.006080  BC0110000  Read-Ack    Relative modulation level: 0.00
15:24:38.846749  T80190000  Read-Data   Boiler water temperature: 0.00
15:24:39.013891  BC0193926  Read-Ack    Boiler water temperature: 57.15
15:24:39.852081  T00090000  Read-Data   Remote override room setpoint: 0.00
15:24:39.861497  R801C0000  Read-Data   Return water temperature: 0.00
15:24:40.012457  B401C279C  Read-Ack    Return water temperature: 39.61
15:24:40.018351  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:24:40.918855  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:40.919374  R801C0000  Read-Data   Return water temperature: 0.00
15:24:41.026219  B401C27A6  Read-Ack    Return water temperature: 39.65
15:24:41.069064  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:42.239382  T901812D4  Write-Data  Room temperature: 18.83
15:24:42.248063  B501812D4  Write-Ack   Room temperature: 18.83
15:24:42.871456  T80000100  Read-Data   Status: 00000001 00000000
15:24:43.012848  B4000010A  Read-Ack    Status: 00000001 00001010
15:24:43.875116  T90013080  Write-Data  Control setpoint: 48.50
15:24:44.008364  B50013080  Write-Ack   Control setpoint: 48.50
15:24:44.880951  T00110000  Read-Data   Relative modulation level: 0.00
15:24:45.008450  BC0110000  Read-Ack    Relative modulation level: 0.00
15:24:45.890665  T80190000  Read-Data   Boiler water temperature: 0.00
15:24:46.011301  BC0193961  Read-Ack    Boiler water temperature: 57.38
15:24:46.927670  T00090000  Read-Data   Remote override room setpoint: 0.00
15:24:46.927923  R801C0000  Read-Data   Return water temperature: 0.00
15:24:47.005140  B401C27E8  Read-Ack    Return water temperature: 39.91
15:24:47.025299  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:24:47.903821  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:47.915997  R801C0000  Read-Data   Return water temperature: 0.00
15:24:48.007550  B401C27F5  Read-Ack    Return water temperature: 39.96
15:24:48.031158  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:49.296335  T806D0000  Read-Data   Electricity producer starts: 0
15:24:49.300653  R00740000  Read-Data   Burner starts: 0
15:24:49.301297  B4074DB40  Read-Ack    Burner starts: 56128
15:24:49.301975  A706D0000  Unk-DataId  Electricity producer starts: 0
15:24:49.916998  T80000100  Read-Data   Status: 00000001 00000000
15:24:50.005777  BC0000102  Read-Ack    Status: 00000001 00000010
15:24:50.959426  T80000100  Read-Data   Status: 00000001 00000000
15:24:51.014188  BC0000102  Read-Ack    Status: 00000001 00000010
15:24:51.932054  T80000100  Read-Data   Status: 00000001 00000000
15:24:52.020162  BC0000102  Read-Ack    Status: 00000001 00000010
15:24:52.938122  T10013099  Write-Data  Control setpoint: 48.60
15:24:53.034068  BD0013099  Write-Ack   Control setpoint: 48.60
15:24:53.944619  T00110000  Read-Data   Relative modulation level: 0.00
15:24:54.103945  BC0110000  Read-Ack    Relative modulation level: 0.00
15:24:54.947441  T80190000  Read-Data   Boiler water temperature: 0.00
15:24:55.105791  BC0193814  Read-Ack    Boiler water temperature: 56.08
15:24:55.958444  T00090000  Read-Data   Remote override room setpoint: 0.00
15:24:55.969098  R80750000  Read-Data   CH pump starts: 0
15:24:56.106881  B4075AF93  Read-Ack    CH pump starts: 44947
15:24:56.116951  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:24:57.124994  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:57.125641  R80760000  Read-Data   DHW pump/valve starts: 0
15:24:57.126080  BC076779E  Read-Ack    DHW pump/valve starts: 30622
15:24:57.131290  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:24:58.346335  T00050000  Read-Data   Application-specific flags: 00000000 0
15:24:58.350840  BC00500FF  Read-Ack    Application-specific flags: 00000000 255
15:24:58.978929  T80000100  Read-Data   Status: 00000001 00000000
15:24:59.102842  BC0000102  Read-Ack    Status: 00000001 00000010
15:24:59.982716  T10013099  Write-Data  Control setpoint: 48.60
15:25:00.000702  Command: SC=15:25/4
15:25:00.122892  SC: 15:25/4
15:25:00.123403  BD0013099  Write-Ack   Control setpoint: 48.60
15:25:00.810980  SC: 15:25/4
15:25:01.030569  T00110000  Read-Data   Relative modulation level: 0.00
15:25:01.115479  BC0110000  Read-Ack    Relative modulation level: 0.00
15:25:01.993978  T80190000  Read-Data   Boiler water temperature: 0.00
15:25:02.124675  BC0193368  Read-Ack    Boiler water temperature: 51.41
15:25:03.020882  T00090000  Read-Data   Remote override room setpoint: 0.00
15:25:03.021215  R00770000  Read-Data   DHW burner starts: 0
15:25:03.120727  BC07752A8  Read-Ack    DHW burner starts: 21160
15:25:03.126061  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:25:04.009344  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:04.020522  R00780000  Read-Data   Burner operation hours: 0
15:25:04.104233  B40780B1B  Read-Ack    Burner operation hours: 2843
15:25:04.118593  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:05.395182  T801B05E6  Read-Data   Outside temperature: 5.90
15:25:05.402981  R80790000  Read-Data   CH pump operation hours: 0
15:25:05.408528  BC079143D  Read-Ack    CH pump operation hours: 5181
15:25:05.409155  A401B0634  Read-Ack    Outside temperature: 6.20
15:25:06.129440  T00000000  Read-Data   Status: 00000000 00000000
15:25:06.136714  B40000002  Read-Ack    Status: 00000000 00000010
15:25:07.029299  T10013099  Write-Data  Control setpoint: 48.60
15:25:07.124383  BD0013099  Write-Ack   Control setpoint: 48.60
15:25:08.034946  T00110000  Read-Data   Relative modulation level: 0.00
15:25:08.135521  BC0110000  Read-Ack    Relative modulation level: 0.00
15:25:09.052571  T80190000  Read-Data   Boiler water temperature: 0.00
15:25:09.201431  B40192ED7  Read-Ack    Boiler water temperature: 46.84
15:25:10.073531  T00090000  Read-Data   Remote override room setpoint: 0.00
15:25:10.074146  R807A0000  Read-Data   DHW pump/valve operation hours: 0
15:25:10.203886  B407A76FE  Read-Ack    DHW pump/valve operation hours: 30462
15:25:10.216173  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:25:11.059055  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:11.065282  R007B0000  Read-Data   DHW burner operation hours: 0
15:25:11.222403  B407B00F1  Read-Ack    DHW burner operation hours: 241
15:25:11.223039  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:12.499645  T900E6400  Write-Data  Maximum relative modulation level: 100.00
15:25:12.509719  B500E6400  Write-Ack   Maximum relative modulation level: 100.00
15:25:13.067672  T00000000  Read-Data   Status: 00000000 00000000
15:25:13.206371  BC0000000  Read-Ack    Status: 00000000 00000000
15:25:14.079967  T00000000  Read-Data   Status: 00000000 00000000
15:25:14.216435  BC0000000  Read-Ack    Status: 00000000 00000000
15:25:15.082073  T00000000  Read-Data   Status: 00000000 00000000
15:25:15.200787  BC0000000  Read-Ack    Status: 00000000 00000000
15:25:16.108257  T900130B3  Write-Data  Control setpoint: 48.70
15:25:16.256104  B500130B3  Write-Ack   Control setpoint: 48.70
15:25:17.090726  T00110000  Read-Data   Relative modulation level: 0.00
15:25:17.207894  BC0110000  Read-Ack    Relative modulation level: 0.00
15:25:18.103561  T80190000  Read-Data   Boiler water temperature: 0.00
15:25:18.205825  B40192B5C  Read-Ack    Boiler water temperature: 43.36
15:25:19.106974  T00090000  Read-Data   Remote override room setpoint: 0.00
15:25:19.115589  R801C0000  Read-Data   Return water temperature: 0.00
15:25:19.205294  B401C283A  Read-Ack    Return water temperature: 40.23
15:25:19.216021  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:25:20.114533  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:20.125549  R801C0000  Read-Data   Return water temperature: 0.00
15:25:20.225246  B401C2842  Read-Ack    Return water temperature: 40.26
15:25:20.225891  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:21.496092  T90101300  Write-Data  Room setpoint: 19.00
15:25:21.499338  B50101300  Write-Ack   Room setpoint: 19.00
15:25:22.133210  T00000000  Read-Data   Status: 00000000 00000000
15:25:22.222457  BC0000000  Read-Ack    Status: 00000000 00000000
15:25:23.134564  T100130CC  Write-Data  Control setpoint: 48.80
15:25:23.258072  BD00130CC  Write-Ack   Control setpoint: 48.80
15:25:24.176475  T00110000  Read-Data   Relative modulation level: 0.00
15:25:24.308203  BC0110000  Read-Ack    Relative modulation level: 0.00
15:25:25.143303  T80190000  Read-Data   Boiler water temperature: 0.00
15:25:25.302393  BC0192A0A  Read-Ack    Boiler water temperature: 42.04
15:25:26.206549  T00090000  Read-Data   Remote override room setpoint: 0.00
15:25:26.207434  R801C0000  Read-Data   Return water temperature: 0.00
15:25:26.308960  BC01C285E  Read-Ack    Return water temperature: 40.37
15:25:26.333985  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:25:27.167647  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:27.168383  R801C0000  Read-Data   Return water temperature: 0.00
15:25:27.304035  BC01C2868  Read-Ack    Return water temperature: 40.41
15:25:27.316088  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:28.539132  T901812D1  Write-Data  Room temperature: 18.82
15:25:28.543245  B501812D1  Write-Ack   Room temperature: 18.82
15:25:29.171565  T00000000  Read-Data   Status: 00000000 00000000
15:25:29.342259  BC0000000  Read-Ack    Status: 00000000 00000000
15:25:30.174877  T100130CC  Write-Data  Control setpoint: 48.80
15:25:30.304231  BD00130CC  Write-Ack   Control setpoint: 48.80
15:25:31.186925  T00110000  Read-Data   Relative modulation level: 0.00
15:25:31.304122  BC0110000  Read-Ack    Relative modulation level: 0.00
15:25:32.259465  T80190000  Read-Data   Boiler water temperature: 0.00
15:25:32.305441  BC0192963  Read-Ack    Boiler water temperature: 41.39
15:25:33.197113  T00090000  Read-Data   Remote override room setpoint: 0.00
15:25:33.210178  R801C0000  Read-Data   Return water temperature: 0.00
15:25:33.312309  B401C2882  Read-Ack    Return water temperature: 40.51
15:25:33.312628  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:25:34.212984  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:34.243199  R801C0000  Read-Data   Return water temperature: 0.00
15:25:34.306745  B401C2882  Read-Ack    Return water temperature: 40.51
15:25:34.317338  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:35.590462  T806E0000  Read-Data   Electricity producer hours: 0
15:25:35.596116  R801C0000  Read-Data   Return water temperature: 0.00
15:25:35.596759  BC01C2885  Read-Ack    Return water temperature: 40.52
15:25:35.600332  A706E0000  Unk-DataId  Electricity producer hours: 0
15:25:36.216042  T00000000  Read-Data   Status: 00000000 00000000
15:25:36.324212  BC0000000  Read-Ack    Status: 00000000 00000000
15:25:37.254137  T100130CC  Write-Data  Control setpoint: 48.80
15:25:37.340177  BD00130CC  Write-Ack   Control setpoint: 48.80
15:25:38.228134  T00110000  Read-Data   Relative modulation level: 0.00
15:25:38.329287  BC0110000  Read-Ack    Relative modulation level: 0.00
15:25:39.237835  T80190000  Read-Data   Boiler water temperature: 0.00
15:25:39.329212  BC019290C  Read-Ack    Boiler water temperature: 41.05
15:25:40.243533  T00090000  Read-Data   Remote override room setpoint: 0.00
15:25:40.252848  R801C0000  Read-Data   Return water temperature: 0.00
15:25:40.399238  B401C289C  Read-Ack    Return water temperature: 40.61
15:25:40.417096  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:25:41.354579  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:41.355438  R801C0000  Read-Data   Return water temperature: 0.00
15:25:41.404241  B401C28A3  Read-Ack    Return water temperature: 40.64
15:25:41.419163  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:42.631965  T00050000  Read-Data   Application-specific flags: 00000000 0
15:25:42.640073  BC00500FF  Read-Ack    Application-specific flags: 00000000 255
15:25:43.283123  T00000000  Read-Data   Status: 00000000 00000000
15:25:43.437127  BC0000000  Read-Ack    Status: 00000000 00000000
15:25:44.300310  T900130E6  Write-Data  Control setpoint: 48.90
15:25:44.401345  B500130E6  Write-Ack   Control setpoint: 48.90
15:25:45.276289  T00110000  Read-Data   Relative modulation level: 0.00
15:25:45.433621  BC0110000  Read-Ack    Relative modulation level: 0.00
15:25:46.296621  T80190000  Read-Data   Boiler water temperature: 0.00
15:25:46.400794  B401928DE  Read-Ack    Boiler water temperature: 40.87
15:25:47.319518  T00090000  Read-Data   Remote override room setpoint: 0.00
15:25:47.320264  R801C0000  Read-Data   Return water temperature: 0.00
15:25:47.437824  BC01C28BA  Read-Ack    Return water temperature: 40.73
15:25:47.438176  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:25:48.300546  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:48.315143  R801C0000  Read-Data   Return water temperature: 0.00
15:25:48.431487  B401C28CC  Read-Ack    Return water temperature: 40.80
15:25:48.432240  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:49.715146  T801B05E6  Read-Data   Outside temperature: 5.90
15:25:49.720667  R801C0000  Read-Data   Return water temperature: 0.00
15:25:49.721242  B401C28CC  Read-Ack    Return water temperature: 40.80
15:25:49.721718  A401B0634  Read-Ack    Outside temperature: 6.20
15:25:50.322662  T00000000  Read-Data   Status: 00000000 00000000
15:25:50.411815  BC0000000  Read-Ack    Status: 00000000 00000000
15:25:51.330054  T900130E6  Write-Data  Control setpoint: 48.90
15:25:51.477972  B500130E6  Write-Ack   Control setpoint: 48.90
15:25:52.329583  T00110000  Read-Data   Relative modulation level: 0.00
15:25:52.422695  BC0110000  Read-Ack    Relative modulation level: 0.00
15:25:53.339726  T80190000  Read-Data   Boiler water temperature: 0.00
15:25:53.505824  B401928CC  Read-Ack    Boiler water temperature: 40.80
15:25:54.346800  T00090000  Read-Data   Remote override room setpoint: 0.00
15:25:54.357570  R00740000  Read-Data   Burner starts: 0
15:25:54.509156  B4074DB40  Read-Ack    Burner starts: 56128
15:25:54.512267  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:25:55.351128  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:55.364453  R80750000  Read-Data   CH pump starts: 0
15:25:55.510062  B4075AF93  Read-Ack    CH pump starts: 44947
15:25:55.517806  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:25:56.754692  T900E6400  Write-Data  Maximum relative modulation level: 100.00
15:25:56.761697  B500E6400  Write-Ack   Maximum relative modulation level: 100.00
15:25:57.501165  T00000000  Read-Data   Status: 00000000 00000000
15:25:57.508894  BC0000000  Read-Ack    Status: 00000000 00000000
15:25:58.376182  T900130E6  Write-Data  Control setpoint: 48.90
15:25:58.513596  B500130E6  Write-Ack   Control setpoint: 48.90
15:25:59.381890  T00110000  Read-Data   Relative modulation level: 0.00
15:25:59.504732  BC0110000  Read-Ack    Relative modulation level: 0.00
15:26:00.000850  Command: SC=15:26/4
15:26:00.041075  SC: 15:26/4
15:26:00.390366  T80190000  Read-Data   Boiler water temperature: 0.00
15:26:00.502483  BC01928C2  Read-Ack    Boiler water temperature: 40.76
15:26:00.812221  SC: 15:26/4
15:26:01.440950  T00090000  Read-Data   Remote override room setpoint: 0.00
15:26:01.441279  R80760000  Read-Data   DHW pump/valve starts: 0
15:26:01.524189  BC076779E  Read-Ack    DHW pump/valve starts: 30622
15:26:01.525008  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:26:02.402077  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:02.415207  R00770000  Read-Data   DHW burner starts: 0
15:26:02.499395  BC07752A8  Read-Ack    DHW burner starts: 21160
15:26:02.515175  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:03.784401  T90101300  Write-Data  Room setpoint: 19.00
15:26:03.789627  B50101300  Write-Ack   Room setpoint: 19.00
15:26:04.427322  T00000000  Read-Data   Status: 00000000 00000000
15:26:04.506929  BC0000000  Read-Ack    Status: 00000000 00000000
15:26:05.427598  T900130E6  Write-Data  Control setpoint: 48.90
15:26:05.517985  B500130E6  Write-Ack   Control setpoint: 48.90
15:26:06.431539  T00110000  Read-Data   Relative modulation level: 0.00
15:26:06.525344  BC0110000  Read-Ack    Relative modulation level: 0.00
15:26:07.504421  T80190000  Read-Data   Boiler water temperature: 0.00
15:26:07.606545  BC01928C2  Read-Ack    Boiler water temperature: 40.76
15:26:08.445594  T00090000  Read-Data   Remote override room setpoint: 0.00
15:26:08.457060  R00780000  Read-Data   Burner operation hours: 0
15:26:08.602824  B40780B1B  Read-Ack    Burner operation hours: 2843
15:26:08.616543  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:26:09.451759  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:09.463673  R80790000  Read-Data   CH pump operation hours: 0
15:26:09.613099  BC079143D  Read-Ack    CH pump operation hours: 5181
15:26:09.613880  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:10.849505  T901812D1  Write-Data  Room temperature: 18.82
15:26:10.856510  B501812D1  Write-Ack   Room temperature: 18.82
15:26:11.480034  T00000000  Read-Data   Status: 00000000 00000000
15:26:11.605290  BC0000000  Read-Ack    Status: 00000000 00000000
15:26:12.473494  T900130E6  Write-Data  Control setpoint: 48.90
15:26:12.604386  B500130E6  Write-Ack   Control setpoint: 48.90
15:26:13.476020  T00110000  Read-Data   Relative modulation level: 0.00
15:26:13.606168  BC0110000  Read-Ack    Relative modulation level: 0.00
15:26:14.500488  T80190000  Read-Data   Boiler water temperature: 0.00
15:26:14.608951  BC01928C7  Read-Ack    Boiler water temperature: 40.78
15:26:15.499033  T00090000  Read-Data   Remote override room setpoint: 0.00
15:26:15.505297  R807A0000  Read-Data   DHW pump/valve operation hours: 0
15:26:15.611278  B407A76FE  Read-Ack    DHW pump/valve operation hours: 30462
15:26:15.615531  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:26:16.547238  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:16.547968  R007B0000  Read-Data   DHW burner operation hours: 0
15:26:16.613419  B407B00F1  Read-Ack    DHW burner operation hours: 241
15:26:16.614021  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:17.888108  T006F0000  Read-Data   Electricity production: 0
15:26:17.899563  R801C0000  Read-Data   Return water temperature: 0.00
15:26:17.900392  B401C291C  Read-Ack    Return water temperature: 41.11
15:26:17.903208  AF06F0000  Unk-DataId  Electricity production: 0
15:26:18.522576  T00000000  Read-Data   Status: 00000000 00000000
15:26:18.611679  BC0000000  Read-Ack    Status: 00000000 00000000
15:26:19.526067  T900130E6  Write-Data  Control setpoint: 48.90
15:26:19.618541  B500130E6  Write-Ack   Control setpoint: 48.90
15:26:20.609600  T00110000  Read-Data   Relative modulation level: 0.00
15:26:20.642909  BC0110000  Read-Ack    Relative modulation level: 0.00
15:26:21.539621  T80190000  Read-Data   Boiler water temperature: 0.00
15:26:21.702007  B401928CC  Read-Ack    Boiler water temperature: 40.80
15:26:22.544729  T00090000  Read-Data   Remote override room setpoint: 0.00
15:26:22.560105  R801C0000  Read-Data   Return water temperature: 0.00
15:26:22.702730  BC01C2930  Read-Ack    Return water temperature: 41.19
15:26:22.714364  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:26:23.557129  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:23.566562  R801C0000  Read-Data   Return water temperature: 0.00
15:26:23.732173  BC01C2935  Read-Ack    Return water temperature: 41.21
15:26:23.733107  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:24.945588  T00050000  Read-Data   Application-specific flags: 00000000 0
15:26:24.952145  BC00500FF  Read-Ack    Application-specific flags: 00000000 255
15:26:25.569861  T00000000  Read-Data   Status: 00000000 00000000
15:26:25.743022  BC0000000  Read-Ack    Status: 00000000 00000000
15:26:26.585624  T90013100  Write-Data  Control setpoint: 49.00
15:26:26.709312  B50013100  Write-Ack   Control setpoint: 49.00
15:26:27.585463  T00110000  Read-Data   Relative modulation level: 0.00
15:26:27.706020  BC0110000  Read-Ack    Relative modulation level: 0.00
15:26:28.594426  T80190000  Read-Data   Boiler water temperature: 0.00
15:26:28.705217  B401928D1  Read-Ack    Boiler water temperature: 40.82
15:26:29.656572  T00090000  Read-Data   Remote override room setpoint: 0.00
15:26:29.657262  R801C0000  Read-Data   Return water temperature: 0.00
15:26:29.705902  B401C2945  Read-Ack    Return water temperature: 41.27
15:26:29.714663  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:26:30.605376  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:30.630485  R801C0000  Read-Data   Return water temperature: 0.00
15:26:30.710209  B401C294C  Read-Ack    Return water temperature: 41.30
15:26:30.716662  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:31.987544  T801B05E6  Read-Data   Outside temperature: 5.90
15:26:31.996407  R801C0000  Read-Data   Return water temperature: 0.00
15:26:32.002149  B401C294C  Read-Ack    Return water temperature: 41.30
15:26:32.006825  A401B0634  Read-Ack    Outside temperature: 6.20
15:26:32.644280  T00000000  Read-Data   Status: 00000000 00000000
15:26:32.716013  BC0000000  Read-Ack    Status: 00000000 00000000
15:26:33.642008  T90013100  Write-Data  Control setpoint: 49.00
15:26:33.815737  B50013100  Write-Ack   Control setpoint: 49.00
15:26:34.636289  T00110000  Read-Data   Relative modulation level: 0.00
15:26:34.727824  BC0110000  Read-Ack    Relative modulation level: 0.00
15:26:35.639985  T80190000  Read-Data   Boiler water temperature: 0.00
15:26:35.802754  BC01928DC  Read-Ack    Boiler water temperature: 40.86
15:26:36.651818  T00090000  Read-Data   Remote override room setpoint: 0.00
15:26:36.666801  R801C0000  Read-Data   Return water temperature: 0.00
15:26:36.850736  B401C2957  Read-Ack    Return water temperature: 41.34
15:26:36.851402  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:26:37.656656  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:37.667186  R801C0000  Read-Data   Return water temperature: 0.00
15:26:37.802973  B401C2951  Read-Ack    Return water temperature: 41.32
15:26:37.812382  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:39.037288  T900E6400  Write-Data  Maximum relative modulation level: 100.00
15:26:39.049073  B500E6400  Write-Ack   Maximum relative modulation level: 100.00
15:26:39.691772  T00000000  Read-Data   Status: 00000000 00000000
15:26:39.803322  BC0000000  Read-Ack    Status: 00000000 00000000
15:26:40.677814  T90013100  Write-Data  Control setpoint: 49.00
15:26:40.807483  B50013100  Write-Ack   Control setpoint: 49.00
15:26:41.719171  T00110000  Read-Data   Relative modulation level: 0.00
15:26:41.801323  BC0110000  Read-Ack    Relative modulation level: 0.00
15:26:42.697874  T80190000  Read-Data   Boiler water temperature: 0.00
15:26:42.803499  B401928EB  Read-Ack    Boiler water temperature: 40.92
15:26:43.700690  T00090000  Read-Data   Remote override room setpoint: 0.00
15:26:43.716113  R801C0000  Read-Data   Return water temperature: 0.00
15:26:43.804416  B401C2968  Read-Ack    Return water temperature: 41.41
15:26:43.815019  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:26:44.713775  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:44.718898  R801C0000  Read-Data   Return water temperature: 0.00
15:26:44.804042  B401C2968  Read-Ack    Return water temperature: 41.41
15:26:44.815311  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:46.091509  T90101300  Write-Data  Room setpoint: 19.00
15:26:46.096633  B50101300  Write-Ack   Room setpoint: 19.00
15:26:46.736979  T00000000  Read-Data   Status: 00000000 00000000
15:26:46.865410  BC0000000  Read-Ack    Status: 00000000 00000000
15:26:47.729714  T90013100  Write-Data  Control setpoint: 49.00
15:26:47.824621  B50013100  Write-Ack   Control setpoint: 49.00
15:26:48.739786  T00110000  Read-Data   Relative modulation level: 0.00
15:26:48.899257  BC0110000  Read-Ack    Relative modulation level: 0.00
15:26:49.746075  T80190000  Read-Data   Boiler water temperature: 0.00
15:26:49.910224  BC01928F8  Read-Ack    Boiler water temperature: 40.97
15:26:50.752123  T00090000  Read-Data   Remote override room setpoint: 0.00
15:26:50.761392  R801C0000  Read-Data   Return water temperature: 0.00
15:26:50.901972  BC01C2982  Read-Ack    Return water temperature: 41.51
15:26:50.914637  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:26:51.853357  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:51.854025  R801C0000  Read-Data   Return water temperature: 0.00
15:26:51.905492  B401C2980  Read-Ack    Return water temperature: 41.50
15:26:51.953676  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:53.142987  T901812D1  Write-Data  Room temperature: 18.82
15:26:53.149418  B501812D1  Write-Ack   Room temperature: 18.82
15:26:53.774133  T00000000  Read-Data   Status: 00000000 00000000
15:26:53.903288  BC0000000  Read-Ack    Status: 00000000 00000000
15:26:54.783145  T90013100  Write-Data  Control setpoint: 49.00
15:26:54.904116  B50013100  Write-Ack   Control setpoint: 49.00
15:26:55.791198  T00110000  Read-Data   Relative modulation level: 0.00
15:26:55.944890  BC0110000  Read-Ack    Relative modulation level: 0.00
15:26:56.797439  T80190000  Read-Data   Boiler water temperature: 0.00
15:26:56.914309  BC0192905  Read-Ack    Boiler water temperature: 41.02
15:26:57.801108  T00090000  Read-Data   Remote override room setpoint: 0.00
15:26:57.813595  R00740000  Read-Data   Burner starts: 0
15:26:57.910296  B4074DB40  Read-Ack    Burner starts: 56128
15:26:57.915101  A40091300  Read-Ack    Remote override room setpoint: 19.00
15:26:58.814401  T00630000  Read-Data   Operating mode HC1, HC2, DHW: 0 0 0 0000
15:26:58.818508  R80750000  Read-Data   CH pump starts: 0
15:26:58.901877  B4075AF93  Read-Ack    CH pump starts: 44947
15:26:58.919671  AC0630000  Read-Ack    Operating mode HC1, HC2, DHW: 0 0 0 0000
15:27:00.000710  Command: SC=15:27/4
15:27:00.196085  T80700000  Read-Data   Cumulative electricity production: 0
15:27:00.203096  R80760000  Read-Data   DHW pump/valve starts: 0
15:27:00.203430  BC076779E  Read-Ack    DHW pump/valve starts: 30622
15:27:00.203670  A70700000  Unk-DataId  Cumulative electricity production: 0
15:27:00.226893  SC: 15:27/4
15:27:00.812853  SC: 15:27/4
15:27:00.827835  T00000000  Read-Data   Status: 00000000 00000000
15:27:00.931975  BC0000000  Read-Ack    Status: 00000000 00000000
15:27:01.828402  T90013100  Write-Data  Control setpoint: 49.00
15:27:01.953727  B50013100  Write-Ack   Control setpoint: 49.00