15:20:48.519648 B4000010A Read-Ack Status: 00000001 00001010 15:20:49.435757 T10015000 Write-Data Control setpoint: 80.00 15:20:49.555479 BD0015000 Write-Ack Control setpoint: 80.00 15:20:50.464644 T00110000 Read-Data Relative modulation level: 0.00 15:20:50.553237 BC0110000 Read-Ack Relative modulation level: 0.00 15:20:51.510143 T80190000 Read-Data Boiler water temperature: 0.00 15:20:51.609916 B4019352E Read-Ack Boiler water temperature: 53.18 15:20:52.451631 T00090000 Read-Data Remote override room setpoint: 0.00 15:20:52.466822 R807A0000 Read-Data DHW pump/valve operation hours: 0 15:20:52.610943 B407A76FE Read-Ack DHW pump/valve operation hours: 30462 15:20:52.618808 A40091300 Read-Ack Remote override room setpoint: 19.00 15:20:53.537911 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:20:53.538257 R007B0000 Read-Data DHW burner operation hours: 0 15:20:53.634791 B407B00F1 Read-Ack DHW burner operation hours: 241 15:20:53.635587 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:20:54.847126 T100E0000 Write-Data Maximum relative modulation level: 0.00 15:20:54.853671 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 15:20:55.473462 T80000100 Read-Data Status: 00000001 00000000 15:20:55.614160 B4000010A Read-Ack Status: 00000001 00001010 15:20:56.477489 T10015000 Write-Data Control setpoint: 80.00 15:20:56.616472 BD0015000 Write-Ack Control setpoint: 80.00 15:20:57.485656 T00110000 Read-Data Relative modulation level: 0.00 15:20:57.628534 BC0110000 Read-Ack Relative modulation level: 0.00 15:20:58.498279 T80190000 Read-Data Boiler water temperature: 0.00 15:20:58.611759 BC01934C0 Read-Ack Boiler water temperature: 52.75 15:20:59.498932 T00090000 Read-Data Remote override room setpoint: 0.00 15:20:59.512477 R801C0000 Read-Data Return water temperature: 0.00 15:20:59.612512 B401C2094 Read-Ack Return water temperature: 32.58 15:20:59.622406 A40091300 Read-Ack Remote override room setpoint: 19.00 15:21:00.000578 Command: SC=15:21/4 15:21:00.038951 SC: 15:21/4 15:21:00.506768 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:00.522710 R801C0000 Read-Data Return water temperature: 0.00 15:21:00.609040 B401C2094 Read-Ack Return water temperature: 32.58 15:21:00.621020 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:00.799185 SC: 15:21/4 15:21:01.892195 T90101300 Write-Data Room setpoint: 19.00 15:21:01.896502 B50101300 Write-Ack Room setpoint: 19.00 15:21:02.520300 T80000100 Read-Data Status: 00000001 00000000 15:21:02.616257 B4000010A Read-Ack Status: 00000001 00001010 15:21:03.530873 T10015000 Write-Data Control setpoint: 80.00 15:21:03.664433 BD0015000 Write-Ack Control setpoint: 80.00 15:21:04.559802 T00110000 Read-Data Relative modulation level: 0.00 15:21:04.621972 BC0110000 Read-Ack Relative modulation level: 0.00 15:21:05.547318 T80190000 Read-Data Boiler water temperature: 0.00 15:21:05.635754 B40193468 Read-Ack Boiler water temperature: 52.41 15:21:06.551591 T00090000 Read-Data Remote override room setpoint: 0.00 15:21:06.564050 R801C0000 Read-Data Return water temperature: 0.00 15:21:06.706340 BC01C207D Read-Ack Return water temperature: 32.49 15:21:06.765021 A40091300 Read-Ack Remote override room setpoint: 19.00 15:21:07.557405 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:07.570188 R801C0000 Read-Data Return water temperature: 0.00 15:21:07.709065 B401C207A Read-Ack Return water temperature: 32.48 15:21:07.733286 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:08.935348 T101812E3 Write-Data Room temperature: 18.89 15:21:08.943291 BD01812E3 Write-Ack Room temperature: 18.89 15:21:09.587956 T80000100 Read-Data Status: 00000001 00000000 15:21:09.709895 B4000010A Read-Ack Status: 00000001 00001010 15:21:10.569942 T10015000 Write-Data Control setpoint: 80.00 15:21:10.710424 BD0015000 Write-Ack Control setpoint: 80.00 15:21:11.586237 T00110000 Read-Data Relative modulation level: 0.00 15:21:11.708949 BC0110000 Read-Ack Relative modulation level: 0.00 15:21:12.591271 T80190000 Read-Data Boiler water temperature: 0.00 15:21:12.712805 B4019341C Read-Ack Boiler water temperature: 52.11 15:21:13.683169 T00090000 Read-Data Remote override room setpoint: 0.00 15:21:13.683801 R801C0000 Read-Data Return water temperature: 0.00 15:21:13.750934 BC01C2066 Read-Ack Return water temperature: 32.40 15:21:13.751628 A40091300 Read-Ack Remote override room setpoint: 19.00 15:21:14.602538 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:14.660874 R801C0000 Read-Data Return water temperature: 0.00 15:21:14.711648 B401C2054 Read-Ack Return water temperature: 32.33 15:21:14.799862 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:15.984532 T80640000 Read-Data Remote override function: 00000000 15:21:16.000708 R801C0000 Read-Data Return water temperature: 0.00 15:21:16.005266 B401C204F Read-Ack Return water temperature: 32.31 15:21:16.005980 A40640303 Read-Ack Remote override function: 00000011 15:21:17.038335 T80000100 Read-Data Status: 00000001 00000000 15:21:17.093831 B4000010A Read-Ack Status: 00000001 00001010 15:21:17.620879 T10015000 Write-Data Control setpoint: 80.00 15:21:17.719329 BD0015000 Write-Ack Control setpoint: 80.00 15:21:18.625364 T00110000 Read-Data Relative modulation level: 0.00 15:21:18.738415 BC0110000 Read-Ack Relative modulation level: 0.00 15:21:19.683151 T80190000 Read-Data Boiler water temperature: 0.00 15:21:19.729480 B401933EE Read-Ack Boiler water temperature: 51.93 15:21:20.643308 T00090000 Read-Data Remote override room setpoint: 0.00 15:21:20.653856 R801C0000 Read-Data Return water temperature: 0.00 15:21:20.809793 BC01C2030 Read-Ack Return water temperature: 32.19 15:21:20.821462 A40091300 Read-Ack Remote override room setpoint: 19.00 15:21:21.654936 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:21.660651 R801C0000 Read-Data Return water temperature: 0.00 15:21:21.806237 BC01C2035 Read-Ack Return water temperature: 32.21 15:21:21.824338 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:23.028179 T00050000 Read-Data Application-specific flags: 00000000 0 15:21:23.042242 BC00500FF Read-Ack Application-specific flags: 00000000 255 15:21:23.665888 T80000100 Read-Data Status: 00000001 00000000 15:21:23.814256 B4000010A Read-Ack Status: 00000001 00001010 15:21:24.695686 T10015000 Write-Data Control setpoint: 80.00 15:21:24.812183 BD0015000 Write-Ack Control setpoint: 80.00 15:21:25.676626 T00110000 Read-Data Relative modulation level: 0.00 15:21:25.814730 BC0110000 Read-Ack Relative modulation level: 0.00 15:21:26.678601 T80190000 Read-Data Boiler water temperature: 0.00 15:21:26.808930 B401933CF Read-Ack Boiler water temperature: 51.81 15:21:27.686174 T00090000 Read-Data Remote override room setpoint: 0.00 15:21:27.692016 R801C0000 Read-Data Return water temperature: 0.00 15:21:27.850074 BC01C2017 Read-Ack Return water temperature: 32.09 15:21:27.850310 A40091300 Read-Ack Remote override room setpoint: 19.00 15:21:28.793054 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:28.793799 R801C0000 Read-Data Return water temperature: 0.00 15:21:28.850279 BC01C200F Read-Ack Return water temperature: 32.06 15:21:28.855510 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:30.073308 T001B05CC Read-Data Outside temperature: 5.80 15:21:30.079467 R801C0000 Read-Data Return water temperature: 0.00 15:21:30.086269 BC01C2000 Read-Ack Return water temperature: 32.00 15:21:30.098483 A401B061A Read-Ack Outside temperature: 6.10 15:21:30.701856 T80000100 Read-Data Status: 00000001 00000000 15:21:30.808779 B4000010A Read-Ack Status: 00000001 00001010 15:21:31.748368 T10015000 Write-Data Control setpoint: 80.00 15:21:31.810568 BD0015000 Write-Ack Control setpoint: 80.00 15:21:32.713857 T00110000 Read-Data Relative modulation level: 0.00 15:21:32.807528 BC0110000 Read-Ack Relative modulation level: 0.00 15:21:33.783166 T80190000 Read-Data Boiler water temperature: 0.00 15:21:33.810299 BC01933AB Read-Ack Boiler water temperature: 51.67 15:21:34.727591 T00090000 Read-Data Remote override room setpoint: 0.00 15:21:34.738843 R00740000 Read-Data Burner starts: 0 15:21:34.818360 B4074DB40 Read-Ack Burner starts: 56128 15:21:34.832993 A40091300 Read-Ack Remote override room setpoint: 19.00 15:21:35.752594 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:35.752937 R80750000 Read-Data CH pump starts: 0 15:21:35.826734 B4075AF93 Read-Ack CH pump starts: 44947 15:21:35.835337 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:37.150295 T100E0000 Write-Data Maximum relative modulation level: 0.00 15:21:37.154227 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 15:21:37.738950 T80000100 Read-Data Status: 00000001 00000000 15:21:38.000896 B4000010A Read-Ack Status: 00000001 00001010 15:21:38.779952 T10015000 Write-Data Control setpoint: 80.00 15:21:38.911803 BD0015000 Write-Ack Control setpoint: 80.00 15:21:39.758094 T00110000 Read-Data Relative modulation level: 0.00 15:21:39.908000 BC0110000 Read-Ack Relative modulation level: 0.00 15:21:40.757842 T80190000 Read-Data Boiler water temperature: 0.00 15:21:40.905231 BC019338F Read-Ack Boiler water temperature: 51.56 15:21:41.767256 T00090000 Read-Data Remote override room setpoint: 0.00 15:21:41.772616 R80760000 Read-Data DHW pump/valve starts: 0 15:21:41.931832 BC076779E Read-Ack DHW pump/valve starts: 30622 15:21:41.932527 A40091300 Read-Ack Remote override room setpoint: 19.00 15:21:42.771668 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:42.791718 R00770000 Read-Data DHW burner starts: 0 15:21:42.909537 BC07752A8 Read-Ack DHW burner starts: 21160 15:21:42.921039 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:44.153292 T90101300 Write-Data Room setpoint: 19.00 15:21:44.158923 B50101300 Write-Ack Room setpoint: 19.00 15:21:44.849916 T80000100 Read-Data Status: 00000001 00000000 15:21:44.910491 B4000010A Read-Ack Status: 00000001 00001010 15:21:45.792445 T10015000 Write-Data Control setpoint: 80.00 15:21:45.915158 BD0015000 Write-Ack Control setpoint: 80.00 15:21:46.798966 T00110000 Read-Data Relative modulation level: 0.00 15:21:46.907692 BC0110000 Read-Ack Relative modulation level: 0.00 15:21:47.801711 T80190000 Read-Data Boiler water temperature: 0.00 15:21:47.910894 BC019336B Read-Ack Boiler water temperature: 51.42 15:21:48.805097 T00090000 Read-Data Remote override room setpoint: 0.00 15:21:48.826198 R00780000 Read-Data Burner operation hours: 0 15:21:48.918980 B40780B1B Read-Ack Burner operation hours: 2843 15:21:48.923036 A40091300 Read-Ack Remote override room setpoint: 19.00 15:21:49.825516 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:49.830595 R80790000 Read-Data CH pump operation hours: 0 15:21:49.908207 BC079143D Read-Ack CH pump operation hours: 5181 15:21:49.918951 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:51.196816 T901812E1 Write-Data Room temperature: 18.88 15:21:51.203018 B501812E1 Write-Ack Room temperature: 18.88 15:21:51.827012 T80000100 Read-Data Status: 00000001 00000000 15:21:51.916635 B4000010A Read-Ack Status: 00000001 00001010 15:21:52.832995 T10015000 Write-Data Control setpoint: 80.00 15:21:52.930820 BD0015000 Write-Ack Control setpoint: 80.00 15:21:53.885443 T00110000 Read-Data Relative modulation level: 0.00 15:21:53.930532 BC0110000 Read-Ack Relative modulation level: 0.00 15:21:54.931303 T80190000 Read-Data Boiler water temperature: 0.00 15:21:55.006926 BC0193345 Read-Ack Boiler water temperature: 51.27 15:21:55.857511 T00090000 Read-Data Remote override room setpoint: 0.00 15:21:55.862019 R807A0000 Read-Data DHW pump/valve operation hours: 0 15:21:56.008790 B407A76FE Read-Ack DHW pump/valve operation hours: 30462 15:21:56.019526 A40091300 Read-Ack Remote override room setpoint: 19.00 15:21:56.906581 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:56.906915 R007B0000 Read-Data DHW burner operation hours: 0 15:21:57.038595 B407B00F1 Read-Ack DHW burner operation hours: 241 15:21:57.039189 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:21:58.240414 T00740000 Read-Data Burner starts: 0 15:21:58.245771 B4074DB40 Read-Ack Burner starts: 56128 15:21:58.865172 T80000100 Read-Data Status: 00000001 00000000 15:21:59.010017 B4000010A Read-Ack Status: 00000001 00001010 15:21:59.881689 T10015000 Write-Data Control setpoint: 80.00 15:22:00.001189 Command: SC=15:22/4 15:22:00.053620 BD0015000 Write-Ack Control setpoint: 80.00 15:22:00.053981 SC: 15:22/4 15:22:00.865171 SC: 15:22/4 15:22:00.885589 T00110000 Read-Data Relative modulation level: 0.00 15:22:01.008334 BC0110000 Read-Ack Relative modulation level: 0.00 15:22:01.890230 T80190000 Read-Data Boiler water temperature: 0.00 15:22:02.010478 B40193328 Read-Ack Boiler water temperature: 51.16 15:22:02.936319 T00090000 Read-Data Remote override room setpoint: 0.00 15:22:02.936981 R801C0000 Read-Data Return water temperature: 0.00 15:22:03.006464 B401C1FB3 Read-Ack Return water temperature: 31.70 15:22:03.018446 A40091300 Read-Ack Remote override room setpoint: 19.00 15:22:03.912206 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:03.913039 R801C0000 Read-Data Return water temperature: 0.00 15:22:04.013665 B401C1FB5 Read-Ack Return water temperature: 31.71 15:22:04.021837 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:05.280102 T00050000 Read-Data Application-specific flags: 00000000 0 15:22:05.289695 BC00500FF Read-Ack Application-specific flags: 00000000 255 15:22:05.915503 T80000100 Read-Data Status: 00000001 00000000 15:22:06.009590 B4000010A Read-Ack Status: 00000001 00001010 15:22:06.973313 T10015000 Write-Data Control setpoint: 80.00 15:22:07.015316 BD0015000 Write-Ack Control setpoint: 80.00 15:22:07.926474 T00110000 Read-Data Relative modulation level: 0.00 15:22:08.034200 BC0110000 Read-Ack Relative modulation level: 0.00 15:22:08.936871 T80190000 Read-Data Boiler water temperature: 0.00 15:22:09.055414 B40193311 Read-Ack Boiler water temperature: 51.07 15:22:09.977920 T00090000 Read-Data Remote override room setpoint: 0.00 15:22:09.978587 R801C0000 Read-Data Return water temperature: 0.00 15:22:10.031325 BC01C1FEB Read-Ack Return water temperature: 31.92 15:22:10.041215 A40091300 Read-Ack Remote override room setpoint: 19.00 15:22:10.954051 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:10.954650 R801C0000 Read-Data Return water temperature: 0.00 15:22:11.109441 BC01C2000 Read-Ack Return water temperature: 32.00 15:22:11.119880 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:12.381882 T001B05CC Read-Data Outside temperature: 5.80 15:22:12.387416 R801C0000 Read-Data Return water temperature: 0.00 15:22:12.388026 BC01C2000 Read-Ack Return water temperature: 32.00 15:22:12.388533 A401B061A Read-Ack Outside temperature: 6.10 15:22:12.955300 T80000100 Read-Data Status: 00000001 00000000 15:22:13.108967 B4000010A Read-Ack Status: 00000001 00001010 15:22:14.069261 T10015000 Write-Data Control setpoint: 80.00 15:22:14.109273 BD0015000 Write-Ack Control setpoint: 80.00 15:22:14.967619 T00110000 Read-Data Relative modulation level: 0.00 15:22:15.109024 BC0110000 Read-Ack Relative modulation level: 0.00 15:22:15.971078 T80190000 Read-Data Boiler water temperature: 0.00 15:22:16.110274 B4019330F Read-Ack Boiler water temperature: 51.06 15:22:16.978569 T00090000 Read-Data Remote override room setpoint: 0.00 15:22:16.988423 R801C0000 Read-Data Return water temperature: 0.00 15:22:17.109038 BC01C202B Read-Ack Return water temperature: 32.17 15:22:17.122028 A40091300 Read-Ack Remote override room setpoint: 19.00 15:22:17.985888 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:17.996525 R801C0000 Read-Data Return water temperature: 0.00 15:22:18.171275 BC01C2035 Read-Ack Return water temperature: 32.21 15:22:18.171971 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:19.380681 T100E0000 Write-Data Maximum relative modulation level: 0.00 15:22:19.384963 BD00E0000 Write-Ack Maximum relative modulation level: 0.00 15:22:20.068669 T80000100 Read-Data Status: 00000001 00000000 15:22:20.107675 B4000010A Read-Ack Status: 00000001 00001010 15:22:21.006278 T10015000 Write-Data Control setpoint: 80.00 15:22:21.108161 BD0015000 Write-Ack Control setpoint: 80.00 15:22:22.009688 T00110000 Read-Data Relative modulation level: 0.00 15:22:22.106889 BC0110000 Read-Ack Relative modulation level: 0.00 15:22:23.022413 T80190000 Read-Data Boiler water temperature: 0.00 15:22:23.106973 BC019331C Read-Ack Boiler water temperature: 51.11 15:22:24.023553 T00090000 Read-Data Remote override room setpoint: 0.00 15:22:24.035197 R801C0000 Read-Data Return water temperature: 0.00 15:22:24.145558 B401C206E Read-Ack Return water temperature: 32.43 15:22:24.145895 A40091300 Read-Ack Remote override room setpoint: 19.00 15:22:25.049935 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:25.055003 R801C0000 Read-Data Return water temperature: 0.00 15:22:25.117394 BC01C2082 Read-Ack Return water temperature: 32.51 15:22:25.134384 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:26.410010 T90101300 Write-Data Room setpoint: 19.00 15:22:26.415527 B50101300 Write-Ack Room setpoint: 19.00 15:22:27.061931 T80000100 Read-Data Status: 00000001 00000000 15:22:27.129092 B4000010A Read-Ack Status: 00000001 00001010 15:22:28.045844 T10015000 Write-Data Control setpoint: 80.00 15:22:28.209055 BD0015000 Write-Ack Control setpoint: 80.00 15:22:29.049961 T00110000 Read-Data Relative modulation level: 0.00 15:22:29.207823 BC0110000 Read-Ack Relative modulation level: 0.00 15:22:30.100606 T80190000 Read-Data Boiler water temperature: 0.00 15:22:30.210321 B40193342 Read-Ack Boiler water temperature: 51.26 15:22:31.065126 T00090000 Read-Data Remote override room setpoint: 0.00 15:22:31.069346 R801C0000 Read-Data Return water temperature: 0.00 15:22:31.208054 BC01C20C0 Read-Ack Return water temperature: 32.75 15:22:31.228788 A40091300 Read-Ack Remote override room setpoint: 19.00 15:22:32.070691 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:32.080288 R801C0000 Read-Data Return water temperature: 0.00 15:22:32.208483 BC01C20E8 Read-Ack Return water temperature: 32.91 15:22:32.220576 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:33.451034 T101812DC Write-Data Room temperature: 18.86 15:22:33.460343 BD01812DC Write-Ack Room temperature: 18.86 15:22:34.080176 T80000100 Read-Data Status: 00000001 00000000 15:22:34.212068 B4000010A Read-Ack Status: 00000001 00001010 15:22:35.088779 T10015000 Write-Data Control setpoint: 80.00 15:22:35.209015 BD0015000 Write-Ack Control setpoint: 80.00 15:22:36.090084 T00110000 Read-Data Relative modulation level: 0.00 15:22:36.211656 BC0110000 Read-Ack Relative modulation level: 0.00 15:22:37.105661 T80190000 Read-Data Boiler water temperature: 0.00 15:22:37.212995 BC0193380 Read-Ack Boiler water temperature: 51.50 15:22:38.102489 T00090000 Read-Data Remote override room setpoint: 0.00 15:22:38.115059 R801C0000 Read-Data Return water temperature: 0.00 15:22:38.212023 BC01C2138 Read-Ack Return water temperature: 33.22 15:22:38.222357 A40091300 Read-Ack Remote override room setpoint: 19.00 15:22:39.112282 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:39.121655 R00740000 Read-Data Burner starts: 0 15:22:39.276529 B4074DB40 Read-Ack Burner starts: 56128 15:22:39.277285 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:40.499585 T00770000 Read-Data DHW burner starts: 0 15:22:40.503127 BC07752A8 Read-Ack DHW burner starts: 21160 15:22:41.127099 T80000100 Read-Data Status: 00000001 00000000 15:22:41.216936 B4000010A Read-Ack Status: 00000001 00001010 15:22:42.134383 T10015000 Write-Data Control setpoint: 80.00 15:22:42.220766 BD0015000 Write-Ack Control setpoint: 80.00 15:22:43.156612 T00110000 Read-Data Relative modulation level: 0.00 15:22:43.248354 BC0110000 Read-Ack Relative modulation level: 0.00 15:22:44.139780 T80190000 Read-Data Boiler water temperature: 0.00 15:22:44.234814 B401933C5 Read-Ack Boiler water temperature: 51.77 15:22:45.165175 T00090000 Read-Data Remote override room setpoint: 0.00 15:22:45.165859 R80750000 Read-Data CH pump starts: 0 15:22:45.311584 B4075AF93 Read-Ack CH pump starts: 44947 15:22:45.322252 A40091300 Read-Ack Remote override room setpoint: 19.00 15:22:46.155992 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:46.163099 R80760000 Read-Data DHW pump/valve starts: 0 15:22:46.312254 BC076779E Read-Ack DHW pump/valve starts: 30622 15:22:46.316833 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:47.533632 T00050000 Read-Data Application-specific flags: 00000000 0 15:22:47.538407 BC00500FF Read-Ack Application-specific flags: 00000000 255 15:22:48.168696 T80000100 Read-Data Status: 00000001 00000000 15:22:48.310069 B4000010A Read-Ack Status: 00000001 00001010 15:22:49.224546 T10015000 Write-Data Control setpoint: 80.00 15:22:49.337937 BD0015000 Write-Ack Control setpoint: 80.00 15:22:50.171788 T00110000 Read-Data Relative modulation level: 0.00 15:22:50.309329 BC0110000 Read-Ack Relative modulation level: 0.00 15:22:51.186301 T80190000 Read-Data Boiler water temperature: 0.00 15:22:51.307621 BC0193417 Read-Ack Boiler water temperature: 52.09 15:22:52.188893 T10012FB3 Write-Data Control setpoint: 47.70 15:22:52.318922 BD0012FB3 Write-Ack Control setpoint: 47.70 15:22:53.192116 T900E6400 Write-Data Maximum relative modulation level: 100.00 15:22:53.310094 B500E6400 Write-Ack Maximum relative modulation level: 100.00 15:22:54.198195 T00090000 Read-Data Remote override room setpoint: 0.00 15:22:54.210106 R00770000 Read-Data DHW burner starts: 0 15:22:54.307308 BC07752A8 Read-Ack DHW burner starts: 21160 15:22:54.322531 A40091300 Read-Ack Remote override room setpoint: 19.00 15:22:55.268156 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:55.268780 R00780000 Read-Data Burner operation hours: 0 15:22:55.309440 B40780B1B Read-Ack Burner operation hours: 2843 15:22:55.318807 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:22:56.588210 T001B05CC Read-Data Outside temperature: 5.80 15:22:56.600025 R80790000 Read-Data CH pump operation hours: 0 15:22:56.600598 BC079143D Read-Ack CH pump operation hours: 5181 15:22:56.616410 A401B061A Read-Ack Outside temperature: 6.10 15:22:57.224102 T80000100 Read-Data Status: 00000001 00000000 15:22:57.317515 B4000010A Read-Ack Status: 00000001 00001010 15:22:58.230237 T10012FB3 Write-Data Control setpoint: 47.70 15:22:58.324029 BD0012FB3 Write-Ack Control setpoint: 47.70 15:22:59.304064 T00110000 Read-Data Relative modulation level: 0.00 15:22:59.330020 BC0110000 Read-Ack Relative modulation level: 0.00 15:23:00.000843 Command: SC=15:23/4 15:23:00.034292 SC: 15:23/4 15:23:00.241571 T80190000 Read-Data Boiler water temperature: 0.00 15:23:00.412399 B40193497 Read-Ack Boiler water temperature: 52.59 15:23:00.857149 SC: 15:23/4 15:23:01.246879 T00090000 Read-Data Remote override room setpoint: 0.00 15:23:01.271417 R807A0000 Read-Data DHW pump/valve operation hours: 0 15:23:01.408714 B407A76FE Read-Ack DHW pump/valve operation hours: 30462 15:23:01.426180 A40091300 Read-Ack Remote override room setpoint: 19.00 15:23:02.253929 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:02.265436 R007B0000 Read-Data DHW burner operation hours: 0 15:23:02.407429 B407B00F1 Read-Ack DHW burner operation hours: 241 15:23:02.472934 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:03.632944 T900E6400 Write-Data Maximum relative modulation level: 100.00 15:23:03.657870 B500E6400 Write-Ack Maximum relative modulation level: 100.00 15:23:04.270541 T80000100 Read-Data Status: 00000001 00000000 15:23:04.465484 B4000010A Read-Ack Status: 00000001 00001010 15:23:05.273675 T10012FB3 Write-Data Control setpoint: 47.70 15:23:05.451464 BD0012FB3 Write-Ack Control setpoint: 47.70 15:23:06.278169 T00110000 Read-Data Relative modulation level: 0.00 15:23:06.408319 BC0110000 Read-Ack Relative modulation level: 0.00 15:23:07.295338 T80190000 Read-Data Boiler water temperature: 0.00 15:23:07.444328 BC01934F5 Read-Ack Boiler water temperature: 52.96 15:23:08.290424 T00090000 Read-Data Remote override room setpoint: 0.00 15:23:08.303449 R801C0000 Read-Data Return water temperature: 0.00 15:23:08.406400 BC01C2335 Read-Ack Return water temperature: 35.21 15:23:08.470342 A40091300 Read-Ack Remote override room setpoint: 19.00 15:23:09.298508 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:09.303776 R801C0000 Read-Data Return water temperature: 0.00 15:23:09.403297 B401C2340 Read-Ack Return water temperature: 35.25 15:23:09.422646 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:10.735016 T90101300 Write-Data Room setpoint: 19.00 15:23:10.738823 B50101300 Write-Ack Room setpoint: 19.00 15:23:11.309055 T80000100 Read-Data Status: 00000001 00000000 15:23:11.435181 B4000010A Read-Ack Status: 00000001 00001010 15:23:12.311052 T10012FE6 Write-Data Control setpoint: 47.90 15:23:12.410195 BD0012FE6 Write-Ack Control setpoint: 47.90 15:23:13.321247 T00110000 Read-Data Relative modulation level: 0.00 15:23:13.407803 BC0110000 Read-Ack Relative modulation level: 0.00 15:23:14.337136 T80190000 Read-Data Boiler water temperature: 0.00 15:23:14.500581 BC0193557 Read-Ack Boiler water temperature: 53.34 15:23:15.333126 T00090000 Read-Data Remote override room setpoint: 0.00 15:23:15.339359 R801C0000 Read-Data Return water temperature: 0.00 15:23:15.426875 B401C239E Read-Ack Return water temperature: 35.62 15:23:15.436471 A40091300 Read-Ack Remote override room setpoint: 19.00 15:23:16.362842 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:16.363173 R801C0000 Read-Data Return water temperature: 0.00 15:23:16.430879 B401C23AE Read-Ack Return water temperature: 35.68 15:23:16.507659 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:17.719435 T901812D7 Write-Data Room temperature: 18.84 15:23:17.724219 B501812D7 Write-Ack Room temperature: 18.84 15:23:18.351103 T80000100 Read-Data Status: 00000001 00000000 15:23:18.421608 Command (via web API from 10.250.250.180:44960): OT=6.2000000000000002 15:23:18.468892 OT: 6.20 15:23:18.507001 B4000010A Read-Ack Status: 00000001 00001010 15:23:19.402689 T10013000 Write-Data Control setpoint: 48.00 15:23:19.502184 BD0013000 Write-Ack Control setpoint: 48.00 15:23:20.366152 T00110000 Read-Data Relative modulation level: 0.00 15:23:20.516508 BC0110000 Read-Ack Relative modulation level: 0.00 15:23:21.369223 T80190000 Read-Data Boiler water temperature: 0.00 15:23:21.506780 B401935B8 Read-Ack Boiler water temperature: 53.72 15:23:22.377963 T00090000 Read-Data Remote override room setpoint: 0.00 15:23:22.387659 R801C0000 Read-Data Return water temperature: 0.00 15:23:22.520910 BC01C241C Read-Ack Return water temperature: 36.11 15:23:22.521719 A40091300 Read-Ack Remote override room setpoint: 19.00 15:23:23.382172 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:23.388943 R801C0000 Read-Data Return water temperature: 0.00 15:23:23.506919 B401C242E Read-Ack Return water temperature: 36.18 15:23:23.518679 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:24.762365 T00780000 Read-Data Burner operation hours: 0 15:23:24.770383 B40780B1B Read-Ack Burner operation hours: 2843 15:23:25.405966 T80000100 Read-Data Status: 00000001 00000000 15:23:25.513583 B4000010A Read-Ack Status: 00000001 00001010 15:23:26.400153 T90013019 Write-Data Control setpoint: 48.10 15:23:26.506647 B50013019 Write-Ack Control setpoint: 48.10 15:23:27.401545 T00110000 Read-Data Relative modulation level: 0.00 15:23:27.507448 BC0110000 Read-Ack Relative modulation level: 0.00 15:23:28.411674 T80190000 Read-Data Boiler water temperature: 0.00 15:23:28.507733 B4019360A Read-Ack Boiler water temperature: 54.04 15:23:29.416887 T00090000 Read-Data Remote override room setpoint: 0.00 15:23:29.430646 R801C0000 Read-Data Return water temperature: 0.00 15:23:29.506887 B401C2482 Read-Ack Return water temperature: 36.51 15:23:29.521818 A40091300 Read-Ack Remote override room setpoint: 19.00 15:23:30.488417 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:30.488711 R801C0000 Read-Data Return water temperature: 0.00 15:23:30.542100 BC01C248C Read-Ack Return water temperature: 36.55 15:23:30.542816 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:31.864713 T00050000 Read-Data Application-specific flags: 00000000 0 15:23:31.869236 BC00500FF Read-Ack Application-specific flags: 00000000 255 15:23:32.468034 T80000100 Read-Data Status: 00000001 00000000 15:23:32.530721 B4000010A Read-Ack Status: 00000001 00001010 15:23:33.446972 T10013033 Write-Data Control setpoint: 48.20 15:23:33.607853 BD0013033 Write-Ack Control setpoint: 48.20 15:23:34.470826 T00110000 Read-Data Relative modulation level: 0.00 15:23:34.609207 BC0110000 Read-Ack Relative modulation level: 0.00 15:23:35.519060 T80190000 Read-Data Boiler water temperature: 0.00 15:23:35.625603 B40193666 Read-Ack Boiler water temperature: 54.40 15:23:36.467589 T00090000 Read-Data Remote override room setpoint: 0.00 15:23:36.471851 R801C0000 Read-Data Return water temperature: 0.00 15:23:36.606427 BC01C2500 Read-Ack Return water temperature: 37.00 15:23:36.616199 A40091300 Read-Ack Remote override room setpoint: 19.00 15:23:37.471048 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:37.478229 R801C0000 Read-Data Return water temperature: 0.00 15:23:37.606025 BC01C2500 Read-Ack Return water temperature: 37.00 15:23:37.665681 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:38.846871 T001B05CC Read-Data Outside temperature: 5.80 15:23:38.853605 R801C0000 Read-Data Return water temperature: 0.00 15:23:38.858312 BC01C2514 Read-Ack Return water temperature: 37.08 15:23:38.864206 A401B0634 Read-Ack Outside temperature: 6.20 15:23:39.504487 T80000100 Read-Data Status: 00000001 00000000 15:23:39.606987 B4000010A Read-Ack Status: 00000001 00001010 15:23:40.500079 T10013033 Write-Data Control setpoint: 48.20 15:23:40.608159 BD0013033 Write-Ack Control setpoint: 48.20 15:23:41.504895 T00110000 Read-Data Relative modulation level: 0.00 15:23:41.606041 BC0110000 Read-Ack Relative modulation level: 0.00 15:23:42.510784 T80190000 Read-Data Boiler water temperature: 0.00 15:23:42.607350 BC01936B5 Read-Ack Boiler water temperature: 54.71 15:23:43.504186 T00090000 Read-Data Remote override room setpoint: 0.00 15:23:43.515160 R801C0000 Read-Data Return water temperature: 0.00 15:23:43.642076 B401C2551 Read-Ack Return water temperature: 37.32 15:23:43.642592 A40091300 Read-Ack Remote override room setpoint: 19.00 15:23:44.512300 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:44.523214 R00740000 Read-Data Burner starts: 0 15:23:44.610399 B4074DB40 Read-Ack Burner starts: 56128 15:23:44.616266 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:45.895674 T900E6400 Write-Data Maximum relative modulation level: 100.00 15:23:45.900070 B500E6400 Write-Ack Maximum relative modulation level: 100.00 15:23:46.641995 T80000100 Read-Data Status: 00000001 00000000 15:23:46.642675 B4000010A Read-Ack Status: 00000001 00001010 15:23:47.531619 T10013033 Write-Data Control setpoint: 48.20 15:23:47.619797 BD0013033 Write-Ack Control setpoint: 48.20 15:23:48.539248 T00110000 Read-Data Relative modulation level: 0.00 15:23:48.629728 BC0110000 Read-Ack Relative modulation level: 0.00 15:23:49.625158 T80190000 Read-Data Boiler water temperature: 0.00 15:23:49.771654 BC0193717 Read-Ack Boiler water temperature: 55.09 15:23:50.546700 T00090000 Read-Data Remote override room setpoint: 0.00 15:23:50.560580 R80750000 Read-Data CH pump starts: 0 15:23:50.722709 B4075AF93 Read-Ack CH pump starts: 44947 15:23:50.728355 A40091300 Read-Ack Remote override room setpoint: 19.00 15:23:51.563766 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:51.586392 R80760000 Read-Data DHW pump/valve starts: 0 15:23:51.706669 BC076779E Read-Ack DHW pump/valve starts: 30622 15:23:51.719351 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:52.936459 T90101300 Write-Data Room setpoint: 19.00 15:23:52.941463 B50101300 Write-Ack Room setpoint: 19.00 15:23:53.568194 T80000100 Read-Data Status: 00000001 00000000 15:23:53.759283 B4000010A Read-Ack Status: 00000001 00001010 15:23:54.593885 T10013033 Write-Data Control setpoint: 48.20 15:23:54.708171 BD0013033 Write-Ack Control setpoint: 48.20 15:23:55.713284 T00110000 Read-Data Relative modulation level: 0.00 15:23:55.717302 BC0110000 Read-Ack Relative modulation level: 0.00 15:23:56.585466 T80190000 Read-Data Boiler water temperature: 0.00 15:23:56.705859 B40193775 Read-Ack Boiler water temperature: 55.46 15:23:57.590104 T00090000 Read-Data Remote override room setpoint: 0.00 15:23:57.604286 R00770000 Read-Data DHW burner starts: 0 15:23:57.706028 BC07752A8 Read-Ack DHW burner starts: 21160 15:23:57.717711 A40091300 Read-Ack Remote override room setpoint: 19.00 15:23:58.604238 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:58.604531 R00780000 Read-Data Burner operation hours: 0 15:23:58.723809 B40780B1B Read-Ack Burner operation hours: 2843 15:23:58.724575 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:23:59.981455 T901812D7 Write-Data Room temperature: 18.84 15:24:00.000659 Command: SC=15:24/4 15:24:00.001491 B501812D7 Write-Ack Room temperature: 18.84 15:24:00.068259 SC: 15:24/4 15:24:00.633443 T80000100 Read-Data Status: 00000001 00000000 15:24:00.712895 B4000010A Read-Ack Status: 00000001 00001010 15:24:00.804197 SC: 15:24/4 15:24:01.615779 T9001304C Write-Data Control setpoint: 48.30 15:24:01.712754 B5001304C Write-Ack Control setpoint: 48.30 15:24:02.622688 T00110000 Read-Data Relative modulation level: 0.00 15:24:02.710014 BC0110000 Read-Ack Relative modulation level: 0.00 15:24:03.627053 T80190000 Read-Data Boiler water temperature: 0.00 15:24:03.721658 BC01937CF Read-Ack Boiler water temperature: 55.81 15:24:04.634768 T00090000 Read-Data Remote override room setpoint: 0.00 15:24:04.643270 R80790000 Read-Data CH pump operation hours: 0 15:24:04.726270 BC079143D Read-Ack CH pump operation hours: 5181 15:24:04.742977 A40091300 Read-Ack Remote override room setpoint: 19.00 15:24:05.646766 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:05.653985 R807A0000 Read-Data DHW pump/valve operation hours: 0 15:24:05.808511 B407A76FE Read-Ack DHW pump/valve operation hours: 30462 15:24:05.813596 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:07.022406 T007B0000 Read-Data DHW burner operation hours: 0 15:24:07.027952 B407B00F1 Read-Ack DHW burner operation hours: 241 15:24:07.655450 T80000100 Read-Data Status: 00000001 00000000 15:24:07.806435 B4000010A Read-Ack Status: 00000001 00001010 15:24:08.674855 T9001304C Write-Data Control setpoint: 48.30 15:24:08.837191 B5001304C Write-Ack Control setpoint: 48.30 15:24:09.664321 T00110000 Read-Data Relative modulation level: 0.00 15:24:09.857349 BC0110000 Read-Ack Relative modulation level: 0.00 15:24:10.668733 T80190000 Read-Data Boiler water temperature: 0.00 15:24:10.805502 BC0193821 Read-Ack Boiler water temperature: 56.13 15:24:11.702324 T00090000 Read-Data Remote override room setpoint: 0.00 15:24:11.703024 R007B0000 Read-Data DHW burner operation hours: 0 15:24:11.823796 B407B00F1 Read-Ack DHW burner operation hours: 241 15:24:11.824099 A40091300 Read-Ack Remote override room setpoint: 19.00 15:24:12.690928 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:12.691561 R801C0000 Read-Data Return water temperature: 0.00 15:24:12.810821 B401C26A1 Read-Ack Return water temperature: 38.63 15:24:12.831534 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:14.070601 T00050000 Read-Data Application-specific flags: 00000000 0 15:24:14.078546 BC00500FF Read-Ack Application-specific flags: 00000000 255 15:24:14.696023 T80000100 Read-Data Status: 00000001 00000000 15:24:14.812765 B4000010A Read-Ack Status: 00000001 00001010 15:24:15.752992 T9001304C Write-Data Control setpoint: 48.30 15:24:15.895565 B5001304C Write-Ack Control setpoint: 48.30 15:24:16.708921 T00110000 Read-Data Relative modulation level: 0.00 15:24:16.814339 BC0110000 Read-Ack Relative modulation level: 0.00 15:24:17.718257 T80190000 Read-Data Boiler water temperature: 0.00 15:24:17.806321 BC0193863 Read-Ack Boiler water temperature: 56.39 15:24:18.724003 T00090000 Read-Data Remote override room setpoint: 0.00 15:24:18.733560 R801C0000 Read-Data Return water temperature: 0.00 15:24:18.812875 BC01C26F0 Read-Ack Return water temperature: 38.94 15:24:18.828443 A40091300 Read-Ack Remote override room setpoint: 19.00 15:24:19.729617 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:19.740314 R801C0000 Read-Data Return water temperature: 0.00 15:24:19.824033 BC01C2702 Read-Ack Return water temperature: 39.01 15:24:19.838561 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:21.109613 T801B05E6 Read-Data Outside temperature: 5.90 15:24:21.128851 R801C0000 Read-Data Return water temperature: 0.00 15:24:21.129449 BC01C2702 Read-Ack Return water temperature: 39.01 15:24:21.130084 A401B0634 Read-Ack Outside temperature: 6.20 15:24:21.799528 T80000100 Read-Data Status: 00000001 00000000 15:24:21.920946 B4000010A Read-Ack Status: 00000001 00001010 15:24:22.747297 T10013066 Write-Data Control setpoint: 48.40 15:24:22.906703 BD0013066 Write-Ack Control setpoint: 48.40 15:24:23.755291 T00110000 Read-Data Relative modulation level: 0.00 15:24:23.906208 BC0110000 Read-Ack Relative modulation level: 0.00 15:24:24.768012 T80190000 Read-Data Boiler water temperature: 0.00 15:24:24.957940 BC01938A6 Read-Ack Boiler water temperature: 56.65 15:24:25.765628 T00090000 Read-Data Remote override room setpoint: 0.00 15:24:25.777365 R801C0000 Read-Data Return water temperature: 0.00 15:24:25.949178 B401C2735 Read-Ack Return water temperature: 39.21 15:24:25.949603 A40091300 Read-Ack Remote override room setpoint: 19.00 15:24:26.798235 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:26.798969 R801C0000 Read-Data Return water temperature: 0.00 15:24:26.913346 BC01C2738 Read-Ack Return water temperature: 39.22 15:24:26.913770 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:28.152652 T900E6400 Write-Data Maximum relative modulation level: 100.00 15:24:28.170334 B500E6400 Write-Ack Maximum relative modulation level: 100.00 15:24:28.782914 T80000100 Read-Data Status: 00000001 00000000 15:24:28.905010 B4000010A Read-Ack Status: 00000001 00001010 15:24:29.797736 T90013080 Write-Data Control setpoint: 48.50 15:24:29.907685 B50013080 Write-Ack Control setpoint: 48.50 15:24:30.820394 T00110000 Read-Data Relative modulation level: 0.00 15:24:30.937139 BC0110000 Read-Ack Relative modulation level: 0.00 15:24:31.816568 T80190000 Read-Data Boiler water temperature: 0.00 15:24:31.904707 B401938E3 Read-Ack Boiler water temperature: 56.89 15:24:32.809050 T00090000 Read-Data Remote override room setpoint: 0.00 15:24:32.820706 R801C0000 Read-Data Return water temperature: 0.00 15:24:32.915446 BC01C2768 Read-Ack Return water temperature: 39.41 15:24:32.915794 A40091300 Read-Ack Remote override room setpoint: 19.00 15:24:33.820916 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:33.826313 R801C0000 Read-Data Return water temperature: 0.00 15:24:33.924335 BC01C276B Read-Ack Return water temperature: 39.42 15:24:33.925124 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:35.210521 T90101300 Write-Data Room setpoint: 19.00 15:24:35.214267 B50101300 Write-Ack Room setpoint: 19.00 15:24:35.828520 T80000100 Read-Data Status: 00000001 00000000 15:24:35.919006 B4000010A Read-Ack Status: 00000001 00001010 15:24:36.833913 T90013080 Write-Data Control setpoint: 48.50 15:24:36.930800 B50013080 Write-Ack Control setpoint: 48.50 15:24:37.862882 T00110000 Read-Data Relative modulation level: 0.00 15:24:38.006080 BC0110000 Read-Ack Relative modulation level: 0.00 15:24:38.846749 T80190000 Read-Data Boiler water temperature: 0.00 15:24:39.013891 BC0193926 Read-Ack Boiler water temperature: 57.15 15:24:39.852081 T00090000 Read-Data Remote override room setpoint: 0.00 15:24:39.861497 R801C0000 Read-Data Return water temperature: 0.00 15:24:40.012457 B401C279C Read-Ack Return water temperature: 39.61 15:24:40.018351 A40091300 Read-Ack Remote override room setpoint: 19.00 15:24:40.918855 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:40.919374 R801C0000 Read-Data Return water temperature: 0.00 15:24:41.026219 B401C27A6 Read-Ack Return water temperature: 39.65 15:24:41.069064 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:42.239382 T901812D4 Write-Data Room temperature: 18.83 15:24:42.248063 B501812D4 Write-Ack Room temperature: 18.83 15:24:42.871456 T80000100 Read-Data Status: 00000001 00000000 15:24:43.012848 B4000010A Read-Ack Status: 00000001 00001010 15:24:43.875116 T90013080 Write-Data Control setpoint: 48.50 15:24:44.008364 B50013080 Write-Ack Control setpoint: 48.50 15:24:44.880951 T00110000 Read-Data Relative modulation level: 0.00 15:24:45.008450 BC0110000 Read-Ack Relative modulation level: 0.00 15:24:45.890665 T80190000 Read-Data Boiler water temperature: 0.00 15:24:46.011301 BC0193961 Read-Ack Boiler water temperature: 57.38 15:24:46.927670 T00090000 Read-Data Remote override room setpoint: 0.00 15:24:46.927923 R801C0000 Read-Data Return water temperature: 0.00 15:24:47.005140 B401C27E8 Read-Ack Return water temperature: 39.91 15:24:47.025299 A40091300 Read-Ack Remote override room setpoint: 19.00 15:24:47.903821 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:47.915997 R801C0000 Read-Data Return water temperature: 0.00 15:24:48.007550 B401C27F5 Read-Ack Return water temperature: 39.96 15:24:48.031158 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:49.296335 T806D0000 Read-Data Electricity producer starts: 0 15:24:49.300653 R00740000 Read-Data Burner starts: 0 15:24:49.301297 B4074DB40 Read-Ack Burner starts: 56128 15:24:49.301975 A706D0000 Unk-DataId Electricity producer starts: 0 15:24:49.916998 T80000100 Read-Data Status: 00000001 00000000 15:24:50.005777 BC0000102 Read-Ack Status: 00000001 00000010 15:24:50.959426 T80000100 Read-Data Status: 00000001 00000000 15:24:51.014188 BC0000102 Read-Ack Status: 00000001 00000010 15:24:51.932054 T80000100 Read-Data Status: 00000001 00000000 15:24:52.020162 BC0000102 Read-Ack Status: 00000001 00000010 15:24:52.938122 T10013099 Write-Data Control setpoint: 48.60 15:24:53.034068 BD0013099 Write-Ack Control setpoint: 48.60 15:24:53.944619 T00110000 Read-Data Relative modulation level: 0.00 15:24:54.103945 BC0110000 Read-Ack Relative modulation level: 0.00 15:24:54.947441 T80190000 Read-Data Boiler water temperature: 0.00 15:24:55.105791 BC0193814 Read-Ack Boiler water temperature: 56.08 15:24:55.958444 T00090000 Read-Data Remote override room setpoint: 0.00 15:24:55.969098 R80750000 Read-Data CH pump starts: 0 15:24:56.106881 B4075AF93 Read-Ack CH pump starts: 44947 15:24:56.116951 A40091300 Read-Ack Remote override room setpoint: 19.00 15:24:57.124994 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:57.125641 R80760000 Read-Data DHW pump/valve starts: 0 15:24:57.126080 BC076779E Read-Ack DHW pump/valve starts: 30622 15:24:57.131290 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:24:58.346335 T00050000 Read-Data Application-specific flags: 00000000 0 15:24:58.350840 BC00500FF Read-Ack Application-specific flags: 00000000 255 15:24:58.978929 T80000100 Read-Data Status: 00000001 00000000 15:24:59.102842 BC0000102 Read-Ack Status: 00000001 00000010 15:24:59.982716 T10013099 Write-Data Control setpoint: 48.60 15:25:00.000702 Command: SC=15:25/4 15:25:00.122892 SC: 15:25/4 15:25:00.123403 BD0013099 Write-Ack Control setpoint: 48.60 15:25:00.810980 SC: 15:25/4 15:25:01.030569 T00110000 Read-Data Relative modulation level: 0.00 15:25:01.115479 BC0110000 Read-Ack Relative modulation level: 0.00 15:25:01.993978 T80190000 Read-Data Boiler water temperature: 0.00 15:25:02.124675 BC0193368 Read-Ack Boiler water temperature: 51.41 15:25:03.020882 T00090000 Read-Data Remote override room setpoint: 0.00 15:25:03.021215 R00770000 Read-Data DHW burner starts: 0 15:25:03.120727 BC07752A8 Read-Ack DHW burner starts: 21160 15:25:03.126061 A40091300 Read-Ack Remote override room setpoint: 19.00 15:25:04.009344 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:04.020522 R00780000 Read-Data Burner operation hours: 0 15:25:04.104233 B40780B1B Read-Ack Burner operation hours: 2843 15:25:04.118593 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:05.395182 T801B05E6 Read-Data Outside temperature: 5.90 15:25:05.402981 R80790000 Read-Data CH pump operation hours: 0 15:25:05.408528 BC079143D Read-Ack CH pump operation hours: 5181 15:25:05.409155 A401B0634 Read-Ack Outside temperature: 6.20 15:25:06.129440 T00000000 Read-Data Status: 00000000 00000000 15:25:06.136714 B40000002 Read-Ack Status: 00000000 00000010 15:25:07.029299 T10013099 Write-Data Control setpoint: 48.60 15:25:07.124383 BD0013099 Write-Ack Control setpoint: 48.60 15:25:08.034946 T00110000 Read-Data Relative modulation level: 0.00 15:25:08.135521 BC0110000 Read-Ack Relative modulation level: 0.00 15:25:09.052571 T80190000 Read-Data Boiler water temperature: 0.00 15:25:09.201431 B40192ED7 Read-Ack Boiler water temperature: 46.84 15:25:10.073531 T00090000 Read-Data Remote override room setpoint: 0.00 15:25:10.074146 R807A0000 Read-Data DHW pump/valve operation hours: 0 15:25:10.203886 B407A76FE Read-Ack DHW pump/valve operation hours: 30462 15:25:10.216173 A40091300 Read-Ack Remote override room setpoint: 19.00 15:25:11.059055 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:11.065282 R007B0000 Read-Data DHW burner operation hours: 0 15:25:11.222403 B407B00F1 Read-Ack DHW burner operation hours: 241 15:25:11.223039 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:12.499645 T900E6400 Write-Data Maximum relative modulation level: 100.00 15:25:12.509719 B500E6400 Write-Ack Maximum relative modulation level: 100.00 15:25:13.067672 T00000000 Read-Data Status: 00000000 00000000 15:25:13.206371 BC0000000 Read-Ack Status: 00000000 00000000 15:25:14.079967 T00000000 Read-Data Status: 00000000 00000000 15:25:14.216435 BC0000000 Read-Ack Status: 00000000 00000000 15:25:15.082073 T00000000 Read-Data Status: 00000000 00000000 15:25:15.200787 BC0000000 Read-Ack Status: 00000000 00000000 15:25:16.108257 T900130B3 Write-Data Control setpoint: 48.70 15:25:16.256104 B500130B3 Write-Ack Control setpoint: 48.70 15:25:17.090726 T00110000 Read-Data Relative modulation level: 0.00 15:25:17.207894 BC0110000 Read-Ack Relative modulation level: 0.00 15:25:18.103561 T80190000 Read-Data Boiler water temperature: 0.00 15:25:18.205825 B40192B5C Read-Ack Boiler water temperature: 43.36 15:25:19.106974 T00090000 Read-Data Remote override room setpoint: 0.00 15:25:19.115589 R801C0000 Read-Data Return water temperature: 0.00 15:25:19.205294 B401C283A Read-Ack Return water temperature: 40.23 15:25:19.216021 A40091300 Read-Ack Remote override room setpoint: 19.00 15:25:20.114533 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:20.125549 R801C0000 Read-Data Return water temperature: 0.00 15:25:20.225246 B401C2842 Read-Ack Return water temperature: 40.26 15:25:20.225891 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:21.496092 T90101300 Write-Data Room setpoint: 19.00 15:25:21.499338 B50101300 Write-Ack Room setpoint: 19.00 15:25:22.133210 T00000000 Read-Data Status: 00000000 00000000 15:25:22.222457 BC0000000 Read-Ack Status: 00000000 00000000 15:25:23.134564 T100130CC Write-Data Control setpoint: 48.80 15:25:23.258072 BD00130CC Write-Ack Control setpoint: 48.80 15:25:24.176475 T00110000 Read-Data Relative modulation level: 0.00 15:25:24.308203 BC0110000 Read-Ack Relative modulation level: 0.00 15:25:25.143303 T80190000 Read-Data Boiler water temperature: 0.00 15:25:25.302393 BC0192A0A Read-Ack Boiler water temperature: 42.04 15:25:26.206549 T00090000 Read-Data Remote override room setpoint: 0.00 15:25:26.207434 R801C0000 Read-Data Return water temperature: 0.00 15:25:26.308960 BC01C285E Read-Ack Return water temperature: 40.37 15:25:26.333985 A40091300 Read-Ack Remote override room setpoint: 19.00 15:25:27.167647 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:27.168383 R801C0000 Read-Data Return water temperature: 0.00 15:25:27.304035 BC01C2868 Read-Ack Return water temperature: 40.41 15:25:27.316088 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:28.539132 T901812D1 Write-Data Room temperature: 18.82 15:25:28.543245 B501812D1 Write-Ack Room temperature: 18.82 15:25:29.171565 T00000000 Read-Data Status: 00000000 00000000 15:25:29.342259 BC0000000 Read-Ack Status: 00000000 00000000 15:25:30.174877 T100130CC Write-Data Control setpoint: 48.80 15:25:30.304231 BD00130CC Write-Ack Control setpoint: 48.80 15:25:31.186925 T00110000 Read-Data Relative modulation level: 0.00 15:25:31.304122 BC0110000 Read-Ack Relative modulation level: 0.00 15:25:32.259465 T80190000 Read-Data Boiler water temperature: 0.00 15:25:32.305441 BC0192963 Read-Ack Boiler water temperature: 41.39 15:25:33.197113 T00090000 Read-Data Remote override room setpoint: 0.00 15:25:33.210178 R801C0000 Read-Data Return water temperature: 0.00 15:25:33.312309 B401C2882 Read-Ack Return water temperature: 40.51 15:25:33.312628 A40091300 Read-Ack Remote override room setpoint: 19.00 15:25:34.212984 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:34.243199 R801C0000 Read-Data Return water temperature: 0.00 15:25:34.306745 B401C2882 Read-Ack Return water temperature: 40.51 15:25:34.317338 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:35.590462 T806E0000 Read-Data Electricity producer hours: 0 15:25:35.596116 R801C0000 Read-Data Return water temperature: 0.00 15:25:35.596759 BC01C2885 Read-Ack Return water temperature: 40.52 15:25:35.600332 A706E0000 Unk-DataId Electricity producer hours: 0 15:25:36.216042 T00000000 Read-Data Status: 00000000 00000000 15:25:36.324212 BC0000000 Read-Ack Status: 00000000 00000000 15:25:37.254137 T100130CC Write-Data Control setpoint: 48.80 15:25:37.340177 BD00130CC Write-Ack Control setpoint: 48.80 15:25:38.228134 T00110000 Read-Data Relative modulation level: 0.00 15:25:38.329287 BC0110000 Read-Ack Relative modulation level: 0.00 15:25:39.237835 T80190000 Read-Data Boiler water temperature: 0.00 15:25:39.329212 BC019290C Read-Ack Boiler water temperature: 41.05 15:25:40.243533 T00090000 Read-Data Remote override room setpoint: 0.00 15:25:40.252848 R801C0000 Read-Data Return water temperature: 0.00 15:25:40.399238 B401C289C Read-Ack Return water temperature: 40.61 15:25:40.417096 A40091300 Read-Ack Remote override room setpoint: 19.00 15:25:41.354579 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:41.355438 R801C0000 Read-Data Return water temperature: 0.00 15:25:41.404241 B401C28A3 Read-Ack Return water temperature: 40.64 15:25:41.419163 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:42.631965 T00050000 Read-Data Application-specific flags: 00000000 0 15:25:42.640073 BC00500FF Read-Ack Application-specific flags: 00000000 255 15:25:43.283123 T00000000 Read-Data Status: 00000000 00000000 15:25:43.437127 BC0000000 Read-Ack Status: 00000000 00000000 15:25:44.300310 T900130E6 Write-Data Control setpoint: 48.90 15:25:44.401345 B500130E6 Write-Ack Control setpoint: 48.90 15:25:45.276289 T00110000 Read-Data Relative modulation level: 0.00 15:25:45.433621 BC0110000 Read-Ack Relative modulation level: 0.00 15:25:46.296621 T80190000 Read-Data Boiler water temperature: 0.00 15:25:46.400794 B401928DE Read-Ack Boiler water temperature: 40.87 15:25:47.319518 T00090000 Read-Data Remote override room setpoint: 0.00 15:25:47.320264 R801C0000 Read-Data Return water temperature: 0.00 15:25:47.437824 BC01C28BA Read-Ack Return water temperature: 40.73 15:25:47.438176 A40091300 Read-Ack Remote override room setpoint: 19.00 15:25:48.300546 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:48.315143 R801C0000 Read-Data Return water temperature: 0.00 15:25:48.431487 B401C28CC Read-Ack Return water temperature: 40.80 15:25:48.432240 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:49.715146 T801B05E6 Read-Data Outside temperature: 5.90 15:25:49.720667 R801C0000 Read-Data Return water temperature: 0.00 15:25:49.721242 B401C28CC Read-Ack Return water temperature: 40.80 15:25:49.721718 A401B0634 Read-Ack Outside temperature: 6.20 15:25:50.322662 T00000000 Read-Data Status: 00000000 00000000 15:25:50.411815 BC0000000 Read-Ack Status: 00000000 00000000 15:25:51.330054 T900130E6 Write-Data Control setpoint: 48.90 15:25:51.477972 B500130E6 Write-Ack Control setpoint: 48.90 15:25:52.329583 T00110000 Read-Data Relative modulation level: 0.00 15:25:52.422695 BC0110000 Read-Ack Relative modulation level: 0.00 15:25:53.339726 T80190000 Read-Data Boiler water temperature: 0.00 15:25:53.505824 B401928CC Read-Ack Boiler water temperature: 40.80 15:25:54.346800 T00090000 Read-Data Remote override room setpoint: 0.00 15:25:54.357570 R00740000 Read-Data Burner starts: 0 15:25:54.509156 B4074DB40 Read-Ack Burner starts: 56128 15:25:54.512267 A40091300 Read-Ack Remote override room setpoint: 19.00 15:25:55.351128 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:55.364453 R80750000 Read-Data CH pump starts: 0 15:25:55.510062 B4075AF93 Read-Ack CH pump starts: 44947 15:25:55.517806 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:25:56.754692 T900E6400 Write-Data Maximum relative modulation level: 100.00 15:25:56.761697 B500E6400 Write-Ack Maximum relative modulation level: 100.00 15:25:57.501165 T00000000 Read-Data Status: 00000000 00000000 15:25:57.508894 BC0000000 Read-Ack Status: 00000000 00000000 15:25:58.376182 T900130E6 Write-Data Control setpoint: 48.90 15:25:58.513596 B500130E6 Write-Ack Control setpoint: 48.90 15:25:59.381890 T00110000 Read-Data Relative modulation level: 0.00 15:25:59.504732 BC0110000 Read-Ack Relative modulation level: 0.00 15:26:00.000850 Command: SC=15:26/4 15:26:00.041075 SC: 15:26/4 15:26:00.390366 T80190000 Read-Data Boiler water temperature: 0.00 15:26:00.502483 BC01928C2 Read-Ack Boiler water temperature: 40.76 15:26:00.812221 SC: 15:26/4 15:26:01.440950 T00090000 Read-Data Remote override room setpoint: 0.00 15:26:01.441279 R80760000 Read-Data DHW pump/valve starts: 0 15:26:01.524189 BC076779E Read-Ack DHW pump/valve starts: 30622 15:26:01.525008 A40091300 Read-Ack Remote override room setpoint: 19.00 15:26:02.402077 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:02.415207 R00770000 Read-Data DHW burner starts: 0 15:26:02.499395 BC07752A8 Read-Ack DHW burner starts: 21160 15:26:02.515175 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:03.784401 T90101300 Write-Data Room setpoint: 19.00 15:26:03.789627 B50101300 Write-Ack Room setpoint: 19.00 15:26:04.427322 T00000000 Read-Data Status: 00000000 00000000 15:26:04.506929 BC0000000 Read-Ack Status: 00000000 00000000 15:26:05.427598 T900130E6 Write-Data Control setpoint: 48.90 15:26:05.517985 B500130E6 Write-Ack Control setpoint: 48.90 15:26:06.431539 T00110000 Read-Data Relative modulation level: 0.00 15:26:06.525344 BC0110000 Read-Ack Relative modulation level: 0.00 15:26:07.504421 T80190000 Read-Data Boiler water temperature: 0.00 15:26:07.606545 BC01928C2 Read-Ack Boiler water temperature: 40.76 15:26:08.445594 T00090000 Read-Data Remote override room setpoint: 0.00 15:26:08.457060 R00780000 Read-Data Burner operation hours: 0 15:26:08.602824 B40780B1B Read-Ack Burner operation hours: 2843 15:26:08.616543 A40091300 Read-Ack Remote override room setpoint: 19.00 15:26:09.451759 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:09.463673 R80790000 Read-Data CH pump operation hours: 0 15:26:09.613099 BC079143D Read-Ack CH pump operation hours: 5181 15:26:09.613880 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:10.849505 T901812D1 Write-Data Room temperature: 18.82 15:26:10.856510 B501812D1 Write-Ack Room temperature: 18.82 15:26:11.480034 T00000000 Read-Data Status: 00000000 00000000 15:26:11.605290 BC0000000 Read-Ack Status: 00000000 00000000 15:26:12.473494 T900130E6 Write-Data Control setpoint: 48.90 15:26:12.604386 B500130E6 Write-Ack Control setpoint: 48.90 15:26:13.476020 T00110000 Read-Data Relative modulation level: 0.00 15:26:13.606168 BC0110000 Read-Ack Relative modulation level: 0.00 15:26:14.500488 T80190000 Read-Data Boiler water temperature: 0.00 15:26:14.608951 BC01928C7 Read-Ack Boiler water temperature: 40.78 15:26:15.499033 T00090000 Read-Data Remote override room setpoint: 0.00 15:26:15.505297 R807A0000 Read-Data DHW pump/valve operation hours: 0 15:26:15.611278 B407A76FE Read-Ack DHW pump/valve operation hours: 30462 15:26:15.615531 A40091300 Read-Ack Remote override room setpoint: 19.00 15:26:16.547238 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:16.547968 R007B0000 Read-Data DHW burner operation hours: 0 15:26:16.613419 B407B00F1 Read-Ack DHW burner operation hours: 241 15:26:16.614021 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:17.888108 T006F0000 Read-Data Electricity production: 0 15:26:17.899563 R801C0000 Read-Data Return water temperature: 0.00 15:26:17.900392 B401C291C Read-Ack Return water temperature: 41.11 15:26:17.903208 AF06F0000 Unk-DataId Electricity production: 0 15:26:18.522576 T00000000 Read-Data Status: 00000000 00000000 15:26:18.611679 BC0000000 Read-Ack Status: 00000000 00000000 15:26:19.526067 T900130E6 Write-Data Control setpoint: 48.90 15:26:19.618541 B500130E6 Write-Ack Control setpoint: 48.90 15:26:20.609600 T00110000 Read-Data Relative modulation level: 0.00 15:26:20.642909 BC0110000 Read-Ack Relative modulation level: 0.00 15:26:21.539621 T80190000 Read-Data Boiler water temperature: 0.00 15:26:21.702007 B401928CC Read-Ack Boiler water temperature: 40.80 15:26:22.544729 T00090000 Read-Data Remote override room setpoint: 0.00 15:26:22.560105 R801C0000 Read-Data Return water temperature: 0.00 15:26:22.702730 BC01C2930 Read-Ack Return water temperature: 41.19 15:26:22.714364 A40091300 Read-Ack Remote override room setpoint: 19.00 15:26:23.557129 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:23.566562 R801C0000 Read-Data Return water temperature: 0.00 15:26:23.732173 BC01C2935 Read-Ack Return water temperature: 41.21 15:26:23.733107 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:24.945588 T00050000 Read-Data Application-specific flags: 00000000 0 15:26:24.952145 BC00500FF Read-Ack Application-specific flags: 00000000 255 15:26:25.569861 T00000000 Read-Data Status: 00000000 00000000 15:26:25.743022 BC0000000 Read-Ack Status: 00000000 00000000 15:26:26.585624 T90013100 Write-Data Control setpoint: 49.00 15:26:26.709312 B50013100 Write-Ack Control setpoint: 49.00 15:26:27.585463 T00110000 Read-Data Relative modulation level: 0.00 15:26:27.706020 BC0110000 Read-Ack Relative modulation level: 0.00 15:26:28.594426 T80190000 Read-Data Boiler water temperature: 0.00 15:26:28.705217 B401928D1 Read-Ack Boiler water temperature: 40.82 15:26:29.656572 T00090000 Read-Data Remote override room setpoint: 0.00 15:26:29.657262 R801C0000 Read-Data Return water temperature: 0.00 15:26:29.705902 B401C2945 Read-Ack Return water temperature: 41.27 15:26:29.714663 A40091300 Read-Ack Remote override room setpoint: 19.00 15:26:30.605376 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:30.630485 R801C0000 Read-Data Return water temperature: 0.00 15:26:30.710209 B401C294C Read-Ack Return water temperature: 41.30 15:26:30.716662 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:31.987544 T801B05E6 Read-Data Outside temperature: 5.90 15:26:31.996407 R801C0000 Read-Data Return water temperature: 0.00 15:26:32.002149 B401C294C Read-Ack Return water temperature: 41.30 15:26:32.006825 A401B0634 Read-Ack Outside temperature: 6.20 15:26:32.644280 T00000000 Read-Data Status: 00000000 00000000 15:26:32.716013 BC0000000 Read-Ack Status: 00000000 00000000 15:26:33.642008 T90013100 Write-Data Control setpoint: 49.00 15:26:33.815737 B50013100 Write-Ack Control setpoint: 49.00 15:26:34.636289 T00110000 Read-Data Relative modulation level: 0.00 15:26:34.727824 BC0110000 Read-Ack Relative modulation level: 0.00 15:26:35.639985 T80190000 Read-Data Boiler water temperature: 0.00 15:26:35.802754 BC01928DC Read-Ack Boiler water temperature: 40.86 15:26:36.651818 T00090000 Read-Data Remote override room setpoint: 0.00 15:26:36.666801 R801C0000 Read-Data Return water temperature: 0.00 15:26:36.850736 B401C2957 Read-Ack Return water temperature: 41.34 15:26:36.851402 A40091300 Read-Ack Remote override room setpoint: 19.00 15:26:37.656656 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:37.667186 R801C0000 Read-Data Return water temperature: 0.00 15:26:37.802973 B401C2951 Read-Ack Return water temperature: 41.32 15:26:37.812382 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:39.037288 T900E6400 Write-Data Maximum relative modulation level: 100.00 15:26:39.049073 B500E6400 Write-Ack Maximum relative modulation level: 100.00 15:26:39.691772 T00000000 Read-Data Status: 00000000 00000000 15:26:39.803322 BC0000000 Read-Ack Status: 00000000 00000000 15:26:40.677814 T90013100 Write-Data Control setpoint: 49.00 15:26:40.807483 B50013100 Write-Ack Control setpoint: 49.00 15:26:41.719171 T00110000 Read-Data Relative modulation level: 0.00 15:26:41.801323 BC0110000 Read-Ack Relative modulation level: 0.00 15:26:42.697874 T80190000 Read-Data Boiler water temperature: 0.00 15:26:42.803499 B401928EB Read-Ack Boiler water temperature: 40.92 15:26:43.700690 T00090000 Read-Data Remote override room setpoint: 0.00 15:26:43.716113 R801C0000 Read-Data Return water temperature: 0.00 15:26:43.804416 B401C2968 Read-Ack Return water temperature: 41.41 15:26:43.815019 A40091300 Read-Ack Remote override room setpoint: 19.00 15:26:44.713775 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:44.718898 R801C0000 Read-Data Return water temperature: 0.00 15:26:44.804042 B401C2968 Read-Ack Return water temperature: 41.41 15:26:44.815311 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:46.091509 T90101300 Write-Data Room setpoint: 19.00 15:26:46.096633 B50101300 Write-Ack Room setpoint: 19.00 15:26:46.736979 T00000000 Read-Data Status: 00000000 00000000 15:26:46.865410 BC0000000 Read-Ack Status: 00000000 00000000 15:26:47.729714 T90013100 Write-Data Control setpoint: 49.00 15:26:47.824621 B50013100 Write-Ack Control setpoint: 49.00 15:26:48.739786 T00110000 Read-Data Relative modulation level: 0.00 15:26:48.899257 BC0110000 Read-Ack Relative modulation level: 0.00 15:26:49.746075 T80190000 Read-Data Boiler water temperature: 0.00 15:26:49.910224 BC01928F8 Read-Ack Boiler water temperature: 40.97 15:26:50.752123 T00090000 Read-Data Remote override room setpoint: 0.00 15:26:50.761392 R801C0000 Read-Data Return water temperature: 0.00 15:26:50.901972 BC01C2982 Read-Ack Return water temperature: 41.51 15:26:50.914637 A40091300 Read-Ack Remote override room setpoint: 19.00 15:26:51.853357 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:51.854025 R801C0000 Read-Data Return water temperature: 0.00 15:26:51.905492 B401C2980 Read-Ack Return water temperature: 41.50 15:26:51.953676 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:53.142987 T901812D1 Write-Data Room temperature: 18.82 15:26:53.149418 B501812D1 Write-Ack Room temperature: 18.82 15:26:53.774133 T00000000 Read-Data Status: 00000000 00000000 15:26:53.903288 BC0000000 Read-Ack Status: 00000000 00000000 15:26:54.783145 T90013100 Write-Data Control setpoint: 49.00 15:26:54.904116 B50013100 Write-Ack Control setpoint: 49.00 15:26:55.791198 T00110000 Read-Data Relative modulation level: 0.00 15:26:55.944890 BC0110000 Read-Ack Relative modulation level: 0.00 15:26:56.797439 T80190000 Read-Data Boiler water temperature: 0.00 15:26:56.914309 BC0192905 Read-Ack Boiler water temperature: 41.02 15:26:57.801108 T00090000 Read-Data Remote override room setpoint: 0.00 15:26:57.813595 R00740000 Read-Data Burner starts: 0 15:26:57.910296 B4074DB40 Read-Ack Burner starts: 56128 15:26:57.915101 A40091300 Read-Ack Remote override room setpoint: 19.00 15:26:58.814401 T00630000 Read-Data Operating mode HC1, HC2, DHW: 0 0 0 0000 15:26:58.818508 R80750000 Read-Data CH pump starts: 0 15:26:58.901877 B4075AF93 Read-Ack CH pump starts: 44947 15:26:58.919671 AC0630000 Read-Ack Operating mode HC1, HC2, DHW: 0 0 0 0000 15:27:00.000710 Command: SC=15:27/4 15:27:00.196085 T80700000 Read-Data Cumulative electricity production: 0 15:27:00.203096 R80760000 Read-Data DHW pump/valve starts: 0 15:27:00.203430 BC076779E Read-Ack DHW pump/valve starts: 30622 15:27:00.203670 A70700000 Unk-DataId Cumulative electricity production: 0 15:27:00.226893 SC: 15:27/4 15:27:00.812853 SC: 15:27/4 15:27:00.827835 T00000000 Read-Data Status: 00000000 00000000 15:27:00.931975 BC0000000 Read-Ack Status: 00000000 00000000 15:27:01.828402 T90013100 Write-Data Control setpoint: 49.00 15:27:01.953727 B50013100 Write-Ack Control setpoint: 49.00